T3-B T6-B Manipulator 11. EMERGENCY
T-B series Rev.1
105
11.1.3 Checking Latch Release Switch Operation
After connecting the safeguard switch and latch release switch to the EMERGENCY
connector, be sure to check the switch operation for safety by following the procedures
described below before operating the Manipulator.
(1)
Turn ON the Manipulator while the safeguard is open in order to boot the controller
software.
(2)
Make sure that “Safety” is displayed on the main window status bar.
(3)
Close the safeguard, and turn ON the switch connecting to the latch release input.
Make sure that the “Safety” is dimmed on the status bar.
The information that the safeguard is open can be latched by software based on the latch
release input condition. To cancel the condition, close the safeguard, and then close the
safeguard latch release input.
Open : The latch release switch latches the condition that the safeguard is open.
Closed : The latch release switch does not latch the condition that the safeguard is open.
The latch release input also functions to acknowledge the change of to TEACH mode.
In order to change the latched condition of TEACH mode, turn the mode selector key switch
on the Teach Pendant to “Auto”. Then, close the latch release input.
11.2 Emergency Stop Switch Connection
11.2.1 Emergency Stop Switch
If it is desired to add an external Emergency Stop switch(es) in addition to the Emergency
Stop on the Teach Pendant and Operator Panel, be sure to connect such Emergency Stop
switch(es) to the Emergency Stop input terminal on the EMERGENCY connector.
The Emergency Stop switch connected must comply with the following and related safety
standard (IEC60947-5-5, etc.):
- It must be a push button switch that is “normally closed”.
- A button that does not automatically return or resume.
- The button must be mushroom-shaped and red.
- The button must have a double contact that is “normally closed”.
The signal from the Emergency Stop switch is designed to use two redundant circuits.
If the signals at the two circuits differ by two seconds or more, the system recognizes it as
a critical error. Therefore, make sure that the Emergency Stop switch has double contacts
and that each circuit connects to the specified pins on the EMERGENCY connector at the
Manipulator. Refer to “
11.4 Circuit Diagrams
”.
Give the emergency stop function to all the equipment which have executable token.
NOTE
NOTE
Содержание T-B Series
Страница 1: ...SCARA ROBOT T B series MANUAL Rev 1 EM217R4788F ...
Страница 2: ...SCARA Robots T B series Manual Rev 1 ...
Страница 15: ...TABLE OF CONTENTS T B series Rev 1 xiii T6 B602S J3 165 Appendix D Open Source Software License 167 ...
Страница 16: ...TABLE OF CONTENTS xiv T B series Rev 1 ...
Страница 17: ...Installation This volume describes the flow from unpacking to operation and designing the robot system ...
Страница 18: ......
Страница 40: ...Installation 5 Second Step 24 T B series Rev 1 ...
Страница 42: ......
Страница 58: ...T3 B T6 B Manipulator 2 Specifications 42 T B series Rev 1 2 3 Outer Dimensions 2 3 1 T3 B ...
Страница 59: ...T3 B T6 B Manipulator 2 Specifications T B series Rev 1 43 2 3 2 T6 B ...
Страница 77: ...T3 B T6 B Manipulator 3 Environments and Installation T B series Rev 1 61 T6 B A B ...
Страница 158: ...T3 B T6 B Manipulator 18 Error Code List 142 T B series Rev 1 ...
Страница 160: ......
Страница 168: ......
Страница 178: ...Appendix B Time and Distance of Free Running in Emergency 162 T B series Rev 1 ...
Страница 182: ...Appendix C Time and Distance of Free Running When Safeguard Is Opened 166 T B series Rev 1 ...