RS3 RS4 Maintenance 4. Cable Unit
RS series Maintenance Rev.3
23
4. Cable Unit
WARNING
■
Do not connect or disconnect the motor connectors while the power to the robot
system is turned ON. Connecting or disconnecting the motor connectors with
the power ON is extremely hazardous and may result in serious bodily injury as
the Manipulator may move abnormally, and also may result in electric shock
and/or malfunction of the robot system.
■
To shut off power to the robot system, disconnect the power plug from the power
source. Be sure to connect the AC power cable to a power receptacle.
DO NOT connect it directly to a factory power source.
■
Before performing any replacement procedure, turn OFF the Controller and
related equipment, and then disconnect the power plug from the power source.
Performing any replacement procedure with the power ON is extremely
hazardous and may result in electric shock and/or malfunction of the robot system.
■
Be careful not to get any foreign substances in the Manipulator, connectors, and
pins during maintenance. Turning ON the power to the robot system when any
foreign substances exist in them is extremely hazardous and may result in electric
shock and/or malfunction of the robot system.
■
Be sure to remove the Manipulator with two or more people.
The Manipulator weight is as follows. Be careful not to get hands, fingers, or feet
caught and/or have equipment damaged by a fall of the Manipulator.
RS3-351* : approx. 17 kg: 38 lb.
RS4-551* : approx. 19 kg: 42 lb.
■
When installing the Manipulator to the ceiling, support the Manipulator, and then
secure the anchor bolts. Removing the support without securing the anchor bolts
properly is extremely hazardous and may result in fall of the Manipulator.
CAUTION
■
Be sure to connect the cables properly. Do not allow unnecessary strain on the
cables. (Do not put heavy objects on the cables. Do not bend or pull the cables
forcibly.) The unnecessary strain on the cables may result in damage to the
cables, disconnection, and/or contact failure. Damaged cables, disconnection,
or contact failure is extremely hazardous and may result in electric shock and/or
improper function of the robot system.
Содержание RS Series
Страница 1: ...Original instructions Rev 3 ENM226R5366F Industrial Robot SCARA ROBOT RS series MAINTENANCE MANUAL ...
Страница 2: ...RS series MAINTENANCE MANUAL Rev 3 ...
Страница 8: ...vi RS series Maintenance Rev 3 ...
Страница 11: ...RS Maintenance This volume contains maintenance procedures with safety precautions for RS series Manipulators ...
Страница 12: ......
Страница 43: ...RS3 RS4 Maintenance 4 Cable Unit RS series Maintenance Rev 3 33 Continued from the previous page ...
Страница 45: ...RS3 RS4 Maintenance 4 Cable Unit RS series Maintenance Rev 3 35 Continued from the previous page ...
Страница 122: ...RS3 RS4 Maintenance 14 Maintenance Parts List 112 RS series Maintenance Rev 3 ...