RS3 RS4 Maintenance 13. Calibration
108
RS series Maintenance Rev.3
(5)-4 Create the data from the calibration point data.
Enter and execute the following command in [Command Window].
(In this example, P1 is used as the calibration point data.)
> Calpls Ppls(
P1
,1), Ppls(
P1
,2), Ppls(
P1
,3), Ppls(
P1
,4)
(5)-5 Move the joint to the specified point using a motion command.
For example, when the specified point data is “P1”,
execute “Jump P1:Z(0)” from [Jog & Teach].
* The joint NOT being calibrated moves to the original position.
(5)-6 Accurately align the joint* being calibrated to the specified point using jog
commands.
* You must move Joint #3 and #4 to the position when calibrating Joint #4.
Select the jog mode [Joint] from [Jog & Teach] to execute the jog motion.
(5)-7 Execute the calibration.
Enter and execute one of the following commands in [Command Window]
according to the joint being calibrated.
Joint #1:
>Calib 1
Joint #2:
>Calib 2
Joint #3:
>Calib 3
Joint #4:
>Calib 3, 4
6.
Accuracy Testing
(6)-1 Move the Manipulator to another point to confirm that it moves to the same position.
If it does not move to the same position, re-calibrate using another point. You must
set the point again if reproducibility cannot be assured through calibration.
Содержание RS Series
Страница 1: ...Original instructions Rev 3 ENM226R5366F Industrial Robot SCARA ROBOT RS series MAINTENANCE MANUAL ...
Страница 2: ...RS series MAINTENANCE MANUAL Rev 3 ...
Страница 8: ...vi RS series Maintenance Rev 3 ...
Страница 11: ...RS Maintenance This volume contains maintenance procedures with safety precautions for RS series Manipulators ...
Страница 12: ......
Страница 43: ...RS3 RS4 Maintenance 4 Cable Unit RS series Maintenance Rev 3 33 Continued from the previous page ...
Страница 45: ...RS3 RS4 Maintenance 4 Cable Unit RS series Maintenance Rev 3 35 Continued from the previous page ...
Страница 122: ...RS3 RS4 Maintenance 14 Maintenance Parts List 112 RS series Maintenance Rev 3 ...