6 Operation
Wellenlötanlage CIG highspeed SIG
DOK-002
6-7
5.3.2
Start screen
Fig. 6-2: Start screen
The start screen displays the following information on the status of the
machine:
a Products located in the machine
b Status messages, warnings and error messages
c General information on the current operating status
d Internal temperature
e Pyrometer temperature
f
Actual solder bath temperature
g Target solder bath temperature
From the start screen, it is possible to:
●
Change the machine operating mode
●
Log users in and out
●
Open windows in which you are able to make settings for controlling
the machine
●
Delete warnings and error messages (see '"Alarm" functional area'
on page 6-25)
2
1
3
4
a
b
c
d
e
f
g