EmoTouch 3 - Installation Instructions
41
Electrical installation
Connection diagram for vaporiser
If the entire output of the vaporisers to be connected exceeds the maxi-
mum switching output (3 kW) of the vaporiser outlet, an additional circuit
breaker must be connected to terminals S1/N/V on the relay box's circuit
board, e.g. LSG18H.
LSG connection
Checking for proper installation of the vaporiser
If installed properly, the vaporiser will switch on and off according to the
humidity setting.
If the
Wb
and
Wm
connections on the vaporiser are swapped, the
vaporiser will not switch off and continue to run uninterrupted.
If the line to
Wm
is disconnected, the
Water shortage
error message has
to appear.
bl
Blue
sw
Black
br
Brown
gn-ge
Green-yellow
PE
Ground potential
Wb
Vaporiser outlet
N
Neutral conductor
WM
Water shortage
A
Audible alarm from vaporiser
B
Lines to relay box
Wm
N
Wb
PE
Wm
N Wb
PE
max. 3 kW
sw
sw
sw
bl
bl
br
sw
gn-ge
B
A
STB
fan
light
FL FN LL LN
L1 L2 L3 N W V U N
N
WB
WM
3 4
S1 S1 N
M A I N S
O V E N
V A P.