44
Installation Instructions - EmoTouch 3
Electrical installation
EN
4
Plug the sensor lines for the sensor into the free jack RJ10 (SENSOR).
The connected sensors are automatically detected and must be
configured on the control panel.
In a multi-cabin installation, the cabin address must also be
programmed. See 7.3 Programming of the cabin address,
Do not establish a connection to the power supply until you have
connected all lines and set all jumpers.
5.5 Connecting and configuring consumers
DANGER
Risk of electric shock
A faulty electrical connection poses the risk of an electric shock.
This risk also applies following completion of the installation work.
Disconnect the system entirely from the mains supply.
If retrofitting is required, the housing must only be opened by
trained personnel.
Electrical installation must only be carried out by a qualified and
licensed electrician.
The unit must be connected to the power supply according to
the circuit diagram and the terminal scheme.
Recommended sequence:
Connect the cabin lighting
Connect the fan
Connect the vaporiser if necessary
Connect the sauna heater
The entire output of the connected devices may not exceed the following
values:
For information about cabin lighting, see Light source requirements:,
For information about the fan, see Fan requirements,
Vaporiser 3 kW
Sauna heaters 9 kW
If the entire output exceeds these values, an additional circuit breaker must
be connected, e.g. LSG18H. See the installation instructions for the relevant
LSG.
Содержание 94 6505 00
Страница 71: ...EmoTouch 3 Installation Instructions 71...