EN
Temperature sensor requirements
CAUTION
Fire hazard from overheating
Requirements that apply to installing the main sensor may exist
for certain sauna heaters.
Before installation, ensure that there are no heater-specific re-
quirements that apply to installing the sensor.
The main sensor (heater sensor) must be installed where expected temper-
atures are the highest, meaning directly above the sauna heater. Proper
installation is necessary to ensure compliance with the temperature limits
and to ensure that there is only a very slight fluctuation in temperature in
the areas of the sauna cabin where there are reclining options.
The main sensor is installed in observance of the following distances from
the cabin wall, depending on the cabin size.
Installation configuration – main sensor (heater sensor) distance from wall
Cabin smaller than 2 x 2 m
Distance from wall 19 cm
Cabin larger than 2 x 2 m
Distance from wall 35 cm
19 cm
35 cm
Cabin smaller than 2x2 m
Cabin larger than 2x2 m