EmoTouch 3 - Installation Instructions
17
Mounting
Line routing
The control line should be routed between the insulation and the outer
wall of the cabin. If it is installed on the cabin wall, it should be routed
through a cable conduit. Cabin insulation must be installed in such a way
that the temperature in the area in which cables are routed cannot exceed
75°C.
Extending the control panel's control line
For longer connections, special RJ10/RJ14 connecting cables with lengths
of 10 m, 25 m, and 50 m are available as an option. A power adapter is
required for cables 25 m or longer.
Alternately, the supplied (as standard) 5 m line can also be extended with
an RJ12/RJ12 coupling and an RJ12/RJ12 extension cord.
The extensions and couplings are available as options.
See Accessories (optional),
4.2 Installation work inside the cabin
At minimum, the cabin lighting and a temperature sensor (main sensor)
must be installed inside the cabin. Additional connections are possible,
depending on the amenities, e.g. coloured lights and audio systems as
optional add-on modules.
All electrical installations and all connecting lines that are installed inside a
sauna cabin must be suitable for an ambient temperature of at least 170°C
and protection class IPx4 or be suitable for use in a steam room (IP 65).
NOTICE
Equipment damage due to improper installation
Additional modules can be mounted in a cabin.
Connect the safety temperature limiter only to the relay box.
Always connect the safety temperature limiter as an isolated
contact.
If the installation uses multiple sauna heaters, multiple safety
temperature limiters may be required. Observe the separate
EOS instructions.