Installation diagram
Installing the temperature sensor in the cabin
1
Determine a suitable location for the installation.
The main sensor (heater sensor) must be installed on the cabin
ceiling above the sauna heater. A second sensor (bench sensor) can
be installed above the back bench.
2
Drill a hole in the cabin ceiling for the cable.
3
NOTICE Do not pull at the plug when routing the control line(s). Doing
so could damage the line. Attach the taut wire only to the cable.
Route the sensor cable through the hole.
4
Open the temperature sensor's housing and connect the sensor bus ca-
ble.
Temperature sensor connections
A
Cabin ceiling
B
Temperature sensor housing
C
RJ10 plug for relay box
D
Line for safety temperature limiter (2-pole)
A
White (sensor bus)
B
Green (sensor bus)
C
Brown (sensor bus)
A
B
C
D
A
B
C
Содержание 94 6505 00