SHOULD YOU ENCOUNTER ANY PROBLEMS INSTALLING THIS UNIT CALL

25

06

 Trouble Shooting  

Fault 

Code

Cause

Action Appliance

Action Installer

E103

Bypass fault

• None.

• (Current too low 

 stepper motor 

not correctly connected or effective; 

current too high 

 short-circuit 

in wiring or stepper motor)

• Disconnect unit from power

• Check connection stepper motor; 

replace wiring or stepper motor

E104

Extract fan defective

• Both fans are switched off. 

• Preheater is switched off.

• If applicable: Postheater 

is switched off.

• Restart every 5 minutes.

• Disconnect unit from power

• Replace extract fan.

• But voltage back on appliance; 

Fault will automatically be reset.

• Check cabling.

E105

Supply fan defective

• Both fans are switched off.

• Preheater is switched off.

• If applicable: Postheater 

is switched off.

• Restart every 5 minutes.

• Disconnect unit from power

• Replace 

• Reconnect unit to power; 

Fault will automatically be reset.

• Check cabling.

E106

The temperature sensor 

that measures the 

outdoor temperature 

is defective

• Both fans are switched off.

• Preheater is switched off.

• Bypass closes and is blocked.

• Disconnect unit from power

• Replace temperature sensor 

• Put voltage back on appliance; 

fault will automatically be reset.

E107

The temperature 

sensor that measures 

the temperature of the 

extract air is defective

• Bypass closes and is blocked.

• Disconnect unit from power

• Replace indoor temperature sensor

E108

If present: The 

temperature sensor that 

measures the external 

temperature is defective

• Postheater is switched off.

• If applicable: Geo heat 

exchanger is switched off.

• Replace external 

temperature sensor

E111

If present: The RH-

sensor that measures 

the humidity is defective

• Appliance continues to operate

• Disconnect unit from power

• Replace RH-sensor.

Dip switches on control 

board not set correctly.

• Appliance does nothing; red 

fault LED on multiple switch 

is not activated either.

• Put dip switches in correct 

position (see page 32).

Note: 

If mode 2 of a multiple switch does not work, the modular connector of the multiple switch has been connected the 

wrong way round. Cut off one of the RJ connectors to the multiple switch and mount a new connector the other way round.

Содержание Slimline 150

Страница 1: ......

Страница 2: ...been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved Children shall not play with the appliance Cleaning and user maintenance shall n...

Страница 3: ...imline 150 unit should include the following components 1 Heat recovery appliance 2 Wall mounting bracket kit 2x suspension strips 3 Duct connecting kit 4x collars 125 mm 4 Documentation set 1x instal...

Страница 4: ...s Compared to the Slimline 150 the Slimline 150 Plus has a more extensive control board which increases the connection options These installation instructions describe both the standard Slimline 150 a...

Страница 5: ...factory setting control unit MAX 4 Way switch 1 2 3 Ventilation capacity m3 h 30 75 100 125 150 Permissible resistance ducts system Pa 2 6 13 38 22 66 35 105 50 150 Rated power excl optional pre heat...

Страница 6: ...power level Lw A Static pressure Pa 10 50 100 25 50 100 50 100 50 100 Housing emission dB A 24 33 39 33 35 40 38 41 44 45 Duct from dwelling dB A 27 36 42 34 37 42 40 43 46 47 Duct to dwelling dB A 4...

Страница 7: ...LLING THIS UNIT PLEASE PASS ONTO END USER DO NOT THROW AWAY 06 1 To dwelling 2 To atmosphere 3 From dwelling 4 From atmosphere 5 Electric connections 6 Connection condensate discharge 02 Technical Spe...

Страница 8: ...ntrol board 9 Connector X4 10 Condensate discharge 11 Supply air filter 12 Preheater 13 Outdoor temperature sensor 14 Heat exchanger 15 Supply fan 16 Modular connector multiple switch 17 Service conne...

Страница 9: ...settings menu see pages 39 41 To prevent freezing of the heat exchanger at extremely low outdoor temperatures the Slimline 150 features an intelligent frost control Temperature sensors measure the tem...

Страница 10: ...om the outside of the appliance If a postheater or extra preheater is connected to connector X14 accessible after opening the front panel the installer must feed the connected 230 Volt cable to outsid...

Страница 11: ...sensor Filter kit 1x G4 1x F7 Transmitter wireless remote control 2 positions with battery Silencer box 125 mm 2x Transmitter wireless remote control 4 positions with battery Silencer air distribution...

Страница 12: ...ppliance flat on the floor because of the position of the condensate discharge bin The installation room must be frost free When mounting flexible ducts bear in mind that it must be possible to replac...

Страница 13: ...INSTALLING THIS UNIT PLEASE PASS ONTO END USER DO NOT THROW AWAY 12 Placing the appliance for ceiling mounted 04 Installation Instructions Appliance disconnecting from mounting bracket Condensate disc...

Страница 14: ...SHOULD YOU ENCOUNTER ANY PROBLEMS INSTALLING THIS UNIT CALL 13 Placing the appliance for wall mounted Condensate discharge Appliance disconnecting from mounting bracket 04 Installation Instructions...

Страница 15: ...sate bin cannot be removed from the appliance for service purposes The condensate discharge line can be mounted toit preferablyglued ifnecessaryusingasquare bend The installer can glue the condensate...

Страница 16: ...heater is installed the rated power increases to 447W Warning The fans and control board carry a high voltage Always remove the voltage from the appliance by isolating power when working on the applia...

Страница 17: ...ing When working on the appliance always remove the voltage from the appliance by first switching it off through software and then isolating the power Connecting Software S1 03 03 08 00 23 00 08 30 23...

Страница 18: ...can be changed by rotating the Right hand setting knob Pressing the Right hand setting knob takes you to the Main Menu Main Menu of the Slimline appliance see page 19 Press the Return key to leave any...

Страница 19: ...anual control key is activated the time interval picture disappears and is replaced by the message Manual When the ventilation flow rate is modified temporarily using the right hand setting knob the t...

Страница 20: ...n or Closed 6 Frost protection active ON or OFF 7 Most recent fault message see page 25 for explanation fault codes Exxx Main menu Pressing the right hand setting knob on the control unit takes you to...

Страница 21: ...ied out for all appliances connected to the control unit B Reset fault codes Reset fault Activating reset fault codes will delete the fault codes list for every individual connected appliance If only...

Страница 22: ...is menu The time is always shown in 24 hours mode B Date Date The current date must be set in this menu since a calendar is programmed in the software the correct day will automatically be shown C Pro...

Страница 23: ...is menu you can select from two underlying menus including Setting step numbers Setting numb Factory setting Factory setting A Setting step numbers Selecting parameter takes you to the overview of all...

Страница 24: ...hismenushowssevencurrentvalues including Current pressure supply in Pa Supply press Current pressure extract in Pa Extract press Current air flow rate supply fan in m3 h Airflow supply Current air flo...

Страница 25: ...t code 06 Trouble Shooting 08 00 23 00 08 30 23 01 12 Sonntag FILTER Sunday 08 00 23 00 08 30 23 01 12 Sonntag E104 When the appliance detects a locking fault it will no longer work The permanently li...

Страница 26: ...e is defective Both fans are switched off Preheater is switched off Bypass closes and is blocked Disconnect unit from power Replace temperature sensor Put voltage back on appliance fault will automati...

Страница 27: ...replacing the filters The filter only has to be cleaned when that is indicated on the display it shows the text FILTER or if a multiple switch with filter indication is mounted when the red LED at th...

Страница 28: ...ER ANY PROBLEMS INSTALLING THIS UNIT CALL 27 07 Maintenance 22 00 07 00 Mittwoch WRG L ftung 01 01 15 14 12 Filter Sonntag 08 30 08 00 23 00 23 01 12 Sonntag 08 30 08 00 23 00 23 01 12 FILTER Sunday S...

Страница 29: ...FTER INSTALLING THIS UNIT PLEASE PASS ONTO END USER DO NOT THROW AWAY 28 B A 07 Maintenance Installer maintenance Swing open the front panel can also be taken from the hinges if required Isolate power...

Страница 30: ...BLEMS INSTALLING THIS UNIT CALL 29 07 Maintenance For ceiling mounting carefully remove the condensate bin there may still be some condensate left in the condensate bin Rinse the exchanger with warm w...

Страница 31: ...AFTER INSTALLING THIS UNIT PLEASE PASS ONTO END USER DO NOT THROW AWAY 30 07 Maintenance...

Страница 32: ...31 07 Maintenance Software S1 03 03 Software S1 03 03 Connecting Connecting 08 00 23 00 08 30 23 01 12 Sonntag FILTER Sunday Filter reset see page 20 Press the Return key to leave any selected menu an...

Страница 33: ...6 C7 C10 C11 Brown Blue Green yellow White nr 1 nr 2 Green Yellow A B C D E F G H J K L M N O P Q R Z Multiple switch Pre heater Outdoor temp sensor Control board Supply fan Extract fan Indoor temp se...

Страница 34: ...e control with the highest set ventilation mode The 4 way switch can also be used to activate a 30 minutes boost mode by putting the switch to setting 3 for less than 2 seconds and directly turning it...

Страница 35: ...nterconnected through eBus Refer to the supplied service tool manual for further instructions There must be a separate 230V fused spur isolator for every appliance Important Because of polarity sensit...

Страница 36: ...Plus are electrically connected to connector X14 just for a postheater there is also a temperature sensor that must be connected to no 7 and 8 of the 9 pole connector that is only installed in the Pl...

Страница 37: ...strain reliever to be installed by the installer not supplied with the appliance for feeding the 230 volt cable to the postheater or extra preheater 1 2 3 4 5 6 7 8 9 X14 1 2 3 4 5 6 7 8 9 X14 Settin...

Страница 38: ...ernal switch contact e g switch or relay contact can be connected to the Slimline 150 Plus If a second input is required as external switch contact if necessary connections no 3 and no 4 can be reprog...

Страница 39: ...iance When replacing a mains cable always order a replacement mains cable from EnviroVent to avoid danger A damaged mains should only be replaced by a qualified person Code 1 Air duct connections 4 pc...

Страница 40: ...uals extract ON imbalance permissible 10 Fixed imbalance 0 m3 h 100 m3 h t m 100 m3 h 1 m3 h STEP NO DESCRIPTION FACTORY SETTING Slimline 150 Plus ADJUSTING RANGE STEP 11 Heater 0 0 no additional heat...

Страница 41: ...lt 0 5 V 22 Conditions switching input 2 0 0 off 1 on 2 On if conditions bypass open satisfied 3 Bypass control 4 Bedroom valve 23 Supply fan mode switching input 2 5 0 Input fan off 1 Absolute min fl...

Страница 42: ...r 1 2 least sensitive STEP NO DESCRIPTION FACTORY SETTING Plus version ADJUSTING RANGE STEP 35 Switching on and off eBUS CO2 sensor OFF ON OFF 36 Min PPM eBUS CO2 sensor 1 400 400 2000 25 37 Max PPM e...

Страница 43: ...ecovery Fan Variable speed EC fan Type of heat exchanger Recuperative plastic cross counterflow heat exchanger Thermal efficiency 83 Maximum flow rate 150 m h Electric power input 64 W Sound power lev...

Страница 44: ...Hornbeam Business Park Harrogate HG2 8PA 01423 810 810 info envirovent com www envirovent com Due to our policy of continuous innovation and improvement EnviroVent reserves the right to alter products...

Отзывы: