AFTER INSTALLING THIS UNIT PLEASE PASS ONTO END USER
DO NOT THROW AWAY
42
Product data sheet conform Ecodesign (EU), nr. 1254/2014 (Annex IV)
Supplier:
EnviroVent
Model:
Slimline 150
Climate zone
Type of control
SEC-Value
in kWh/m²/a
Energy class (SEC)
The annual electricity
consumption (AEC)
in kWh
The annual heating
saved (AHS)
in kWh
Average
Clock
-34,08
A
438
4435
1 Sensor (RH/CO2/VOC)
-36,49
A
396
4389
2 or more Sensors (RH/CO
2
/VOC)
-40,67
A+
314
4496
Cold
Clock
-76,03
A+
975
6617
1 Sensor (RH/CO2/VOC)
-78,94
A+
933
6698
2 or more Sensors (RH/CO2/VOC)
-84,16
A+
851
6862
Warm
Clock
-10,06
E
393
2282
1 Sensor (RH/CO2/VOC)
-12,16
E
351
2310
2 or more Sensors (RH/CO2/VOC)
-15,75
E
269
2366
Type of ventilation unit:
Ventilation unit with heat recovery
Fan:
Variable speed EC fan
Type of heat exchanger:
Recuperative plastic cross-counterflow heat exchanger
Thermal efficiency:
83%
Maximum flow rate:
150 m³/h
Electric power input:
64 W
Sound power level Lwa:
38 dB(A)
Reference flow rate :
105 m³/h
Reference pressure difference:
50Pa
Specific Power Input (SEL):
0,33 W/m³/h
Control factor:
1,0 in combination with manual switch
0,95 in combination with clock
0,85 in combination with 1 sensor
0,65 in combination with 2 or more sensors
Leakage*:
Internal
0,9%
External
2,3%
Filter warning:
On the display of the ventilation unit / Manual switch / clock control.
Attention! For optimal energy efficiency and a proper operation a regular filter
inspection, cleaning or replacement is necessary.
Internet address for Assembly instructions:
www.envirovent.com
Bypass:
Yes; 100% Bypass
*Measurements executed by TNO according to the EN 13141-7 standard (TNO-report TNO 2014 R10659, April 2014)
12
ErP