INPUTS & OUTPUTS
Outputs
124 |
P a g e
Copyright © 2021 BF ENTRON and/or its affiliates. All rights reserved
Product Model:
iPAK2v2
Firmware Version:
V2.10
May 22 | Doc No 700253-2
7.2
Outputs
The outputs from the iPAK2v2 are defined in
. The physical location of the Pin location for the Discrete connects
Output
Discrete
Connection
Port-Pin
AWS
designation
Description
EOS
P3-14
EH1
This output switches on to
indicate the end of the weld
sequence.
HAV
P3-4
RV1
Used in conjunction with the
Retract input to control the
welding head.
Fault
P3-15
FT1
This output indicates a fault
condition.
Ready
1
P3-16
This output is active if iPAK2v2
is ready to weld. The output
switches off under some fault
conditions.
Contactor
P3-17
MC1
This output can be used to
control an isolation contactor.
Counter / tip
dress request
P3-6
This output indicates that the
counter has reached its limit or
that a tip dressing operation is
required.
Stepper
P3-7
This output indicates that the
stepper has reached its limit.
Pre-warn
P3-8
This output indicates that the
stepper is close to its limit.
AV8
P3-13
Additional outputs that can be
used during the weld sequence
to control valves etc.
AV7
P3-12
AV6
P3-11
AV5
P3-10
AV4
P3-9
AV3
P3-3
AV2
P3-2
AV1
P3-1
1. If iPAK (v1) mode is selected (see
section)
* the sense of the READY output is reversed and it signifies NOT READY
* outputs AV4, 5, and 6 are used for MUX selection and are not available
Table 45: Outputs List