INPUTS & OUTPUTS
Inputs
123 |
P a g e
Copyright © 2021 BF ENTRON and/or its affiliates. All rights reserved
Product Model:
iPAK2v2
Firmware Version:
V2.10
May 22 | Doc No 700253-2
Input
Discrete
Connection
Port-Pin
AWS
designation
Description
Reset counter /
tip dress
acknowledge
3
P2-13
Used to reset the counter(s) or acknowledge a
tip dress request.
Reset stepper
4
P2-12
SR1
Used to reset the stepper(s).
P1
P2-6
BP1
Program select inputs. Weld program selection
is made by applying the binary code for the
required program. Programs 0 to 127 can be
selected via the discrete interface. Programs 0
to 255 can be selected internally, via Modbus
or via EtherNet/IP.
If the ‘key
-
switch’ security option is selected,
then input P64 (on the discrete interface only)
is not available. In this case, programs 0 to 63
can be selected (programs 64 to 255 can still
be selected internally or via the fieldbus).
P2
P2-7
BP2
P4
P2-8
BP4
P8
P2-9
BP8
P16
P2-10
BP16
P32
P2-11
BP32
P64 / Edit enable
5
P2-17
BP64
P128
N/A
BP128
1. The discrete connection for this input is
always
required, even when the I/O source is Modbus or
EtherNet/IP.
2. The signal from the discrete interface is
always
used, even when the I/O source is Modbus or
EtherNet/IP where there is no equivalent signal.
3. Momentary operation will reset all expired counters. If maintained for more than 5 seconds all counters
will be reset, regardless of status.
4. Momentary operation will reset all expired steppers. If maintained for more than 5 seconds all steppers
will be reset, regardless of status.
5. The Edit enable function is only available on the Discrete interface. This bit is always P128 on other
interfaces.
6. Input is only accessible through EtherNet/IP and MODBUS. No Discrete connection exists.
Table 44: Inputs List