UNCONTROLLED COPY WHEN DOWNLOADED OR PRINTED
ENSTROM F-28F/280F SERIES MAINTENANCE MANUAL SUPPLEMENT 1
Rev.
5
7-8
Apr
15/15
8) Configure Contrast Configuration Page with the following parameters:
CONTRAST
Configuration
Page
Notes
Adjust
Contrast
per
customer
requirement
CONTRAST
MODE
AUTO
50
9) Configure VFR Key Configuration Page with the following parameters:
VFR
KEY
Configuration
Page
Notes
VFR
KEY
ENABLE
10) Configure ARINC 429 Configuration Page with the following parameters:
ARINC
429
Configuration
Page
Notes
429
INPUT
SPEED
DATA
CHANNEL
1
LOW
OFF
CHANNEL
2
LOW
OFF
429
INPUT
SPEED
DATA
CHANNEL
3
LOW
OFF
CHANNEL
4
OFF
429
OUTPUT
DATA
CHANNEL
1
OFF
CHANNEL
2
OFF
11) Configure RS-232 Input/Output Page with the following parameters:
RS
‐
232
INPUT/OUTPUT
Page
Notes
RS232
INPUT
OUTPUT
For
remote
operation
and
ADS
‐
B
position
source
from
GTN
650
CHNL
1
REMOTE
REMOTE
CHNL
2
OFF
OFF
12) Configure Operation Configuration Page with the following parameters:
OPERATION
Configuration
Page
Notes
VS
RATE
0500
FORMAT
FEET
VFR
ID
1200
ALT
ALRT
DEV
200ft
SQUAT
SWITCH?
YES
SENSE
LOW
DELAY
TIME
3
AUTO
FLT
TMR?
MAN
Visit www.enstromhelicopter.com for instructions to order an original manual and to register for email notification of updates.