UNCONTROLLED COPY WHEN DOWNLOADED OR PRINTED
ENSTROM F-28F/280F SERIES MAINTENANCE MANUAL SUPPLEMENT 1
Rev.
1
2-3
Nov
21/08
SECTION 3
SERVICING, TROUBLESHOOTING, AND PERIODIC INSPECTIONS
3-1. Servicing
A. The Sandia SAE5-35 contains no user serviceable components or assemblies.
Operations involving the removal of the Sandia SAE5-35 or any other line-replaceable unit
(LRU) installed as a part of the Sandia SAE5-35 must be done by authorized maintenance
technicians.
B. The Sandia SAE5-35 requires calibration every 24 mouths. Refer to the
installation manual when calibrating the Sandia SAE5-35.
3-2. Troubleshooting
A. No troubleshooting guidelines are available for the Sandia SAE5-35.
3-3. Periodic
Inspections
A. The following inspection checklist is intended as a guide for 100 hour/annual
inspections for aircraft operating under normal conditions. More frequent inspections may
be required should adverse operating conditions be encountered.
Date
Signature
Aircraft Registration Number
Aircraft Serial Number
SANDIA SAE5-35 ALTITUDE DATA SYSTEM
INITIAL EACH ITEM AFTER ACCOMPLISHMENT
Inspect the following items every 100 hours or annually
INITIAL
1. Inspect the electrical cables, and mounts for security, damage,
and obvious defects.
Visit www.enstromhelicopter.com for instructions to order an original manual and to register for email notification of updates.