8.1
General error messages
The following table shows the possible error messages of the status display:
Displayed
error code
Meaning
Measures for error rectification
1
Error code not present
2
Power stage temperature
greater than 85°C
Check installation conditions. Environmental temperature too
high? If necessary, provide appropriate cooling.
3
Error code not present
4
DC-link voltage greater than
maximum value
Regenerative feedback mode. If necessary, adjust ramp or
provide external voltage limiting.
5
Angle sensor error
internal defect, no remedy possible
6
Undervoltage
Check input voltage. Error occurs eventually with powerful,
short-term accelerations.
7
Overcurrent
Motor currents and control parameters of the current controller
parameterised in accordance with factory specifications?
8
Checksum parameter memory
The contents of the parameter memory were read incorrectly.
Does
the
error
occur
again
after
restarting?
Download a well-proven parameter set or
Check the parameter settings with DSerV service software
and save with
OPTIMISATION / SAVE SETTINGS
.
9
Faulty parameter set
The parameter set transferred by "Download" is faulty. The
download cannot be saved.
Switch the device off and on in order to activate a
previously saved parameter set or
Use a different parameter set.
10
Internal error
No remedy by the user. DSerV displays an additional error
number for Error 10, which provides an indication of the cause
of error.
11
Positioning error
DSerV displays an additional error number for Error 11, which
provides an indication of the cause of error.
See chapter 8.2 Error messages in positioning mode
12
Fieldbus error
Errors of the fieldbus interface.
See chapter 8.4 CAN bus error messages