Enertech Global
66
EAV - EME/EMD Rev. A Models
Installation and Operations Manual
Wiring Diagram Selection
Diagram
Application
Distribution System
Controls
Heating (Radiant Floor, Fan
Coil, Both)
Cooling (Fan
Coil)
Min. Fan Coil
Size
Zone Control
Thermostat**
APPLICATIONS WITH HYDRAULIC SEPARATOR (PIPING DIAGRAMS IN FIGURE 12B)
HTG-1
Heating Only
Up to 6 Radiant Floor
Zones-- NOTE 1
N/A
N/A
ATEZVCA
NOTE 2
HTGCLG-1
Heating/
Cooling
Both (Up to 5 Radiant/One
Fan Coil) -- NOTE 3
One Fan Coil --
NOTE 3
2 tons
HCC-NN-WVC-ZM
NOTE 2
HTGCLG-2
Heating/
Cooling (with
Duct Zoning)
Both (Up to 5 Radiant/One
Fan Coil with Duct Zoning)
-- NOTE 3
One Fan Coil
with EWC Duct
Zoning -- NOTE 3
2 tons
HCC-NN-WVC-ZM
NOTE 2
HTGCLG-3
Heating/
Cooling (dual
fuel)
Both (Up to 5 Radiant/One
A-Coil [dual fuel]) -- NOTE 3
"One A-Coil
(dual fuel)
-- NOTE 3"
2 tons
HCC-NN-WVC-ZM
NOTE 4
HTGCLG-4
Heating/
Cooling (Fan
Coils Only)
Up to 3 MPH Series Air
Handler/Fan Coil Units
Up to 3 Air
Handler /Fan
Coil Units --
NOTE 5
2 tons
AZUZC-4
AT_ _ _ _ _ _
HTGCLG-5
Heating/
Cooling (Fan
Coils Only)
Up to 3 Air Y/W Type Air
Handler /Fan Coil Units
Up to 3 Air
Handler /Fan
Coil Units --
NOTE 6
2 tons
AZUZC-4
AT_ _ _ _ _ _
APPLICATIONS WITH BUFFER TANK (PIPING DIAGRAM IN FIGURE 12D)
HTGCLG-6
Heating/
Cooling (with
Buffer Tank)
Both (Up to 6 Radiant or Fan
Coil Zones)
Up to 6 Air
Handler /Fan
Coil Units --
NOTE 7
No minimum HCC-NN-HC1-ZM
NOTE 2
**See thermostat chart for details
Notes:
1.
More than 6 zones requires another zone control for each additional 6 zones.
2.
Use AT_ _ _ _ _ _ for fan coil zone(s); use 29001, THM-0100, or THM-0200 for radiant zones. THM and 29001 models are dual
sensing.
3.
For additional zones, an expansion panel is required, HCE-NN-WVC-ZM. Each expansion panel provides an additional fan coil
zone and 5 additional radiant zones. IMPORTANT: If fan coil/A-Coil will be used for heating, a call for forced air heating will
provide a Y2 signal to the EAV unit (120
O
F water). If 120
O
F water to the floor is not acceptable, a dual sensing thermostat is
required to limit floor temp.
4.
Zone 1 requires a dual fuel heat pump thermostat (disable compressor during second stage heating). 29001, THM-0100 or
THM-0200 (dual sensing) recommended for radiant zones.For Enertech MPH fan coils. Uses EWC zone panel. Does not require a
master zone. System may switch back and forth between heating and cooling. For more than 3 zones, use part # AZZXM-2 two
zone expansion panel.
5.
For Multi-Aqua and non-Enertech fan coils. Uses EWC zone panel. Does not require a master zone. System may switch back and
forth between heating and cooling. For more than 3 zones, use part # AZZXM-2 two zone expansion panel.
6.
Requires buffer tank.
Zone Controls
Section 8: Field Wiring