Enertech Global
27
EAV - EME/EMD Rev. A Models
Installation and Operations Manual
Section 4: Dimensional and Physical Data
LOAD
HOT WATER
FROM WV
DOMESTIC
HOT WATER
LOAD
WATER
TO WV
DOMESTIC
COLD WATER
DRAIN VALVE
A
B
C
D
F
E
TANK PRESSURE
RELIEF VALVE
AUTOMATIC
AIR PURGER
TEMP. & PRESS.
INDICATOR
OU LET
T
Load Hot Water/
Antifreeze from EAV
Domestic
Hot Water
Automatic
Air Purger
Temp. & Press
Indicator
Tank Pressure
Relief Valve
Domestic
Cold Water
Load Water
Outlet to EAV
Drain Valve
⚠
WARNING
⚠
SEE FIGURE 12E FOR PIPING
PRECAUTIONS
Hot Water Capacities ‡
EAV
Model
TURBOMAX
Model
Water Heater
Rated
Capacity
(U.S. Gallons)
Typical
Household
(# of people)
1st Hour
Rating
(GHP)*
Recovery In
GPH (60
o
F)
Comparable
Electric Water
Heater
(Gallons)***
Comparable
Gas Water
Heater
(Gallons)***
030
45
48
2 to 4
70
135
97
67
65
72
3 to 5
90
135
120
90
060
45
48
3 to 5
100
178
200
170
65
72
5 to 7
125
178
209
179
* First hour rating (in gallons per hour) is the amount of hot water a fully heated tank can deliver in one hour.
** Recovery is the volume (in gallons) that can be heated in one hour from initial water temperature on the cold line to
the temperature rise specified by the manufacturer. Enertech uses a 60
O
F temperature rise.
*** Storage required to compare to the EAV, using am electric water heater with two interlocked 4,500 Watt elements or
a gas water heater with 40,000 Btuh input.
‡
IMPORTANT NOTE:
Capacities shown are at 47°F Outdoor Air Temp (OAT). At colder temperatures, capacities are lower. For example, at 10°F, the
capacity is approximately 1/2 of the capacity at 47°F. A backup water heater is recommended.
TURBOMAX
Model
Dimensions (inches)
Approximate
Shipping
Weight (lbs)
A
B
C
D
E
F
45
55.00
50.50
9.50
5.75
4.00
22.00
235 lbs
65
67.00
60.50
9.50
6.50
4.00
24.00
250 lbs