Enertech Global
28
EAV - EME/EMD Rev. A Models
Installation and Operations Manual
EAV Outdoor Unit Electrical Data
20D237‐27NN: AV Electrical Data
Volts
Phase
HP
FLA
AV030
1
208/230
1
1/5
0.85
26.6
45
AV060
1
208/230
1
1/5
0.85
45.9
80
Max
Fuse
HACR
Drive
Min
Circuit
Amps
Notes:
1. All line and low voltage wiring must adhere to the National Electrical Code and local codes, whichever is the most
stringent.
2. In determining the correct supply wire size and maximum length, reference NFPA 70, Section 310. If the calculation is
close to the maximum allowable ampacity of a particular wire size, use the next size up. This will ensure that no adverse
effects occur, such as light dimming and/or shortened compressor life.
3. All fuses class RK-5.
4. Min/Max Voltage: 208/230/60 = 187-252
5. CMCC (Compressor Maximum Output Current Limit): This value is the maximum output of the dirve (inverter) to the
compressor. Although not significant to the installation (continue to use MCA for wire/breaker sizing), this value is a required
listing for the unit electrical data.
Model
Voltage
Code
60 Hz Power
Compressor
36.0
Fan
LRA
20.6
50.0
50.0
CMCC
5
20D237‐26NN: EM Electrical Data
Volts
Phase
Volts
kW
FLA
HP
FLA
EMD000
1
208/230
1
1/4
1.5
3.4
15
EME000
1
208/230
1
230
9
39.1
1/4
1.5
52.7
60
Model
Voltage
Code
60 Hz Power
Notes:
1. All line and low voltage wiring must adhere to the National Electrical Code and local codes, whichever is the
most stringent.
2. In determining the correct supply wire size and maximum length, reference NFPA 70, Section 310. If the
calculation is close to the maximum allowable ampacity of a particular wire size, use the next size up. This will
ensure that no adverse effects occur, such as light dimming and/or shortened compressor life.
3. All fuses class RK-5.
4. Min/Max Voltage: 208/230/60 = 187-252
Immersion Heater
Min
Circuit
AMPS
Max
Fuse
HACR
Internal Pump
Section 5: Electrical Data
EME/EMD Indoor Module Electrical Data