26
3. Carefully pull the DC connector apart.
4. Release the clamping bracket. To do so, insert a flat-blade screwdriver (blade width:
3.5 mm) into the clamping bracket and lever it open.
5. Remove the cable.
5.5.4 Connecting the PV array
Destruction of the inverter due to overvoltage
If the voltage of the strings exceeds the maximum DC input voltage of the inverter,
it can be destroyed due to overvoltage. All warranty claims become void.
• Do not connect strings with an open-circuit voltage greater than the maximum
DC input voltage of the inverter.
• Check the design of the PV system.
1. Ensure that the individual miniature circuit-breaker is switched off and ensure that it
cannot be accidentally reconnected.
2. Ensure that the DC switch is switched off and ensure that it cannot be accidentally
reconnected.
3. Ensure that there is no ground fault in the PV array.
Содержание GPV3.6KTL
Страница 6: ......