38
Object
Description
A
Normal (Green LED)
B
Communication (B
lue
LED)
C
Fault (Red LED)
Green LED:
The green LED is lit when the inverter is operating normally. The green LED is off The
inverter is not feeding into the grid.
The inverter is equipped with a dynamic power display via the green LED. Depending
on the power, the green LED pulses fast or slow.If the power is less than 45% of
power,the green LED pulses slow.If the power is greater than 45% of power and less
than 90% of power ,the green LED pulses fast.The green LED is glowing when the
inverter is in Feed-in operation with a power of at least 90% of power.
Blue LED:
The blue LED flashes during communication with other devices e.g.
AiCom/AiManager, Solarlog etc. Also, the blue LED flashes during firmware update
through RS485.
Red LED:
The red LED is lit when the inverter has stopped feeding power into the grid due to a
fault. The corresponding error code will be shown on the display.
8 Disconnecting the Inverter from Voltage Sources
Prior to performing any work on the inverter, disconnect it from all voltage sources as
described in this section. Always adhere strictly to the prescribed sequence.
Destruction of the measuring device due to overvoltage
• Only use measuring devices with a DC input voltage range of 580 V or higher.
Procedure: