11
Risk of injury due to damaged cables
There may be power cables or other supply lines (e.g. gas or water) routed in the
wall.
• Ensure that no lines are laid in the wall which could be damaged when drilling
holes.
1. Use the wall bracket as a drilling template and mark the positions of the drill holes.
Drill 3 holes with a 10 mm drill. The holes must be about 70 mm deep. Keep the drill
vertical to the wall, and hold the drill steady to avoid tilted holes.
Risk of injury due to the inverter falls down
•Before inserting the wall anchors, measure the depth and distance of the holes.
•If the measured values do not meet the hole requirements,redrill
the holes.
2. After drilling holes in the wall, place three screw anchors into the holes, then attach
the wall mounting bracket to the wall using the self-tapping screws delivered with the
inverter.