Pin6-------RX_RS485B
Pin7-------+7V
Pin8-------+7V
The network cable meeting the EIA/TIA 568A or 568B standard must be UV resistant if
it is to be used outdoors.
Cable requirement :
- Shielding wire
- CAT-5E or higher
- UV-resistant for outdoor use
- RS485 cable maximum length 1000m
Procedure:
1. Take out the cable fixing accessory from the package.
2. Unscrew the swivel nut of the M25 cable gland, remove the filler-plug from the cable
gland and keep it well. If there is only one network cable, please keep a filler-plug in
the remaining hole of the sealing ring against water ingress.
3. Current pin assignment for the network cable as per EIA/TIA 568 standard:
4. Route the cable into the inverter through the M25 cable gland, and pass through the
magnetic ring, then connect it.
1
2
3
4
5. Connect the inverter to AiCom or another communication device via the
above-mentioned network cable. The inverter have two RJ45 interfaces with the
same function. If there is only one network cable, you can use any of them.