Proline Prosonic Flow 90
6 Commissioning
Hauser
67
6.3
Commissioning via a configuration program
6.3.1
Sensor installation
For sensor installation with the configuration program “ToF Tool - Fieldtool Package” any “Quick
Setup” menus which correspond to the local operation exist.
Other methods (see table) are available for determining the relevant values for sensor distance, wire
length, etc. The procedure is illustrated in detail on
Sensor type
Required values for
the sensor mounting
procedure
Local display
1)
ToF Tool - Fieldtool
Package
2)
Applicator
3)
clamp-on
version
Sensor position
x
x
x
Wire length
x
x
x
Sensor distance
x
x
x
Insertion
version
Sensor distance
x
x
x
Arc length
x
x
x
Path length
x
x
x
1)
Conditions that must be met before determining the values via the local display using the
“Sensor” Quick Setup (see Page 64):
• Transmitter installed (see Page 32)
• Transmitter connected to power supply (see Page 37)
2)
ToF Tool - Fieldtool Package is a configuration and service software for flowmeters in the
field. Conditions that must be met before determining the values via the “ToF Tool - Field-
tool Package”:
• Transmitter installed (see Page 32)
• Transmitter connected to power supply (see Page 37)
• ToF Tool - Fieldtool Package configuration and service software installed on a note-
book/PC
• Connection made between notebook/PC and device via the FXA 193 service interface
3)
Applicator is a software for selecting and configuring flowmeters. The values required can
be determined without having to connect the transmitter beforehand.
The “Applicator” can be downloaded from the Internet (
→
www.applicator.com
) or
ordered on CD-ROM for installation on a local PC.
Содержание Prosonic Flow 90
Страница 4: ...Brief operating instructions Proline Prosonic Flow 90 4 Endress Hauser...
Страница 42: ...4 Wiring Proline Prosonic Flow 90 42 Endress Hauser...
Страница 62: ...5 Operation Proline Prosonic Flow 90 62 Endress Hauser...
Страница 74: ...7 Maintenance Proline Prosonic Flow 90 74 Endress Hauser...
Страница 78: ...8 Accessories Proline Prosonic Flow 90 78 Endress Hauser...
Страница 94: ...9 Trouble shooting Proline Prosonic Flow 90 94 Endress Hauser...
Страница 108: ...10 Technical data Proline Prosonic Flow 90 108 Endress Hauser...
Страница 112: ...Index Proline Prosonic Flow 90 112 Endress Hauser...
Страница 114: ...www endress com worldwide BA068D 06 en 11 04 50099981 FM SGLM6 0...