Proline Promag L 800
Installation
Hauser
15
Installation in down pipes
Install a siphon or a vent valve downstream of the sensor in down pipes whose length h
5 m
(16.4 ft), (
6). This precaution is to avoid low pressure and the consequent risk of damage
to the lining of the measuring tube. This measure also prevents the system losing prime, which
could cause air pockets.
Detailed information on the lining's resistance to partial vacuum:
Operating Instructions for the device on the enclosed CD-ROM
A0017064
Fig. 6: Measures for installation in a down pipe
1
Vent valve
2
Pipe siphon
h
Length of down pipe, h
5 m (16.4 ft)
Installation in partially filled pipes with a gradient
Partially filled pipes with gradients necessitate a drain-type configuration.
"
Caution!
Risk of solids accumulating.
• Do not install the sensor at the lowest point in the drain.
• It is advisable to install a cleaning valve.
A0017063
Fig. 7: Installation in a partially filled pipe
h
2
1
³
5 x DN
³
2 x DN