System information
The information in Table 4.1 must be entered into the Gammapilot in the commissioning
phase of the calibration:
Example for
commissioning
For a Gammapilot operating with a horizontally mounted DG 57 detector and Cs137
source, calibration date Friday, October 16th 1992, the following must be entered:
Step
Matrix
Entry
Significance
1
V3H0
5
Select standard calibration with background calibration
(Section4.2) or
2
for auxiliary calibration (Section 4.4)
or
1
without background calibration (Section 4.3)
2
-
»E«
Registers entry
3
V3H1
0
Cs137 source
4
-
»E«
Registers entry
5
V3H2
0
DG 57 detector
6
-
»E«
Registers entry
7
V3H3
0
Detector mounted horizontally
8
-
»E«
Registers entry
9
V3H4
2425
1992, week 42, Friday
10
-
»E«
Registers entry
11
…
…
Continue with calibration to Section 4.2, 4.3, or 4.4
During this procedure the alarm LED flashes and Warning 630 is generated to indicate
that the calibration is incomplete.
Parameter
Matrix
Significance
Source type
V3H1
0 =
Cs137
1 =
Co60
Detector type
V3H2
0 =
DG 57
1 =
DG 17
2 =
DG 27
Detector orientation
V3H3
0 =
Horizontal (or vertical)
1 =
Head on
Calibration date
V3H4
Date on which calibration was made
Y =
Last digit of year, e.g. 2 for 1992
WW = Calender week, e.g. 23 for week 23
D =
Day, e.g. 1 = Monday, 2 = Tuesday
Y WW D
Table 4.7:
System information required for
commissioning
Gammapilot FTG 671
Chapter 4: Calibration and Operation
32
Содержание gammapilot FTG 671
Страница 4: ...Gammapilot FTG 671 Table of Contents 2...
Страница 12: ...Gammapilot FTG 671 Chapter 1 Introduction 10...
Страница 28: ...Gammapilot FTG 671 Chapter 2 Installation 26...
Страница 32: ...Gammapilot FTG 671 Chapter 3 Controls 30...
Страница 48: ...Gammapilot FTG 671 Chapter 5 Limit Switches Relays 46...
Страница 50: ...Gammapilot FTG 671 Chapter 6 Maintenance 48...
Страница 59: ...Gammapilot FTG 671 Operating Matrix 57...
Страница 61: ...Index Gammapilot FTG 671 59...
Страница 62: ...Gammapilot FTG 671 Index 60...
Страница 63: ...Index Gammapilot FTG 671 61...