17
English
MAINTENANCE
The following procedures must be followed when maintenance or
service is performed on the air compressor.
1. Ensure
On/Off switch is in the OFF position
.
2. Remove air compressor plug from outlet.
3. Drain air tank.
4. Allow air compressor to cool down before starting service.
noTE:
All compressed air systems contain maintenance parts
(e.g., oil, filters, separators) that are periodically replaced. These
used parts may contain substances that are regulated and must be
disposed of in accordance with local, state, and federal laws and
regulations.
noTE:
Take note of the positions and locations of parts during
disassembly to make reassembly easier.
noTE:
Any service operations not included in this section should
be performed by an authorized service center.
Maintenance Chart
procedure
Daily Weekly Monthly
1 year
or 200
Hours
see tank
warning label
Check safety valve
X
Inspect air
X
Drain air tank
X
Check pump oil level
X
Change pump oil**+
X
Oil leak inspection
X
Check for unusual noise/
vibration
X
Check for air leaks*
X
procedure
Daily Weekly Monthly
1 year
or 200
Hours
see tank
warning label
Clean compressor exterior
X
Remove tank from service
X
** The pump oil must be changed after the first 20 hours of operation.
Thereafter, when using
ISO 100/SAE40, non-detergent, premium air
compressor oil
, change oil every 200 hours of operation or once a year,
whichever comes first.
+ Perform more frequent in dusty or humid conditions
Remove tank from service. For more information, call our Customer
Care Center at
1-888-88E
M
GLO (1-888-883-6456)
Checking Safety Valve (Fig. 1)
WARNING
: Hot surfaces. Risk of burn. Aftercooler, pump head,
and surrounding parts are very hot, do not touch (see the Hot
Surfaces identified in Fig. 2). Allow compressor to cool prior to
servicing.
WARNING:
Risk of bursting. If the safety valve does not work
properly, over-pressurization may occur, causing air tank rupture or
an explosion.
Before starting compressor, pull the ring on the safety valve to
make sure that the safety valve operates freely. If the valve is
stuck or does not operate smoothly, it must be replaced with the
same type of valve.
Checking Air Filter Element (Fig. 1)
WARNING
: Hot surfaces. Risk of burn. Aftercooler, pump head,
and surrounding parts are very hot, do not touch (see the Hot
Surfaces identified in Fig. 2). Allow compressor to cool prior to
servicing.