Assembly and installation
6
Assembly
6.1
ELDRO-EdEx-Montageanleitung-607338-EN.docx
45
/ 75
6.1.1
Permissible installation positions
Vertical and intermediate positions up to 60° deviation from the
vertical position (marking "II"):
– Lifting rod acting upwards without restrictions
– Lifting rod acting downwards is not permissible.
Horizontal and intermediate positions up to 30° deviation from
the horizontal position (marking "I"):
– it is necessary to contact the manufacturer (
⇒
General
chapter, Manufacturer section).
6.1.2
Installing the EdEx thruster
Preparatory measures
The following checks must be carried out before the EdEx thruster is
installed:
The EdEx thruster must not exhibit any damage or other
conspicuous changes (if necessary also check for damage to the
packaging).
The IP protection class of the EdEx thruster must correspond
with the operating and environmental conditions.
The zones are defined by the operating company.
Check whether the thruster category corresponds to the
specified zones
Check whether the thruster category of other attachments (e.g.
sensors) corresponds to the specified zones
Check the product documentation to see whether upstream
safety devices (e.g. power fuses) are required
Specification of explosion protection requirements:
– Safety-related characteristics for potentially explosive
substances
– Zone areas
– Ambient temperatures
Содержание ELDRO EdEx 125/160
Страница 2: ......