7
Notes on operation
7.1
Safety instructions
56
/ 75
ELDRO-EdEx-Montageanleitung-607338-EN.docx
7
Notes on operation
7.1
Safety instructions
Never operate the EdEx thruster with electrical connections that
are faulty or not ready for operation.
The EdEx thruster must be operated exclusively with the
hydraulic medium specified on the type plate. (Depending on the
hydraulic medium used, operation of the EdEx thruster is limited
to the specified ambient temperatures.)
The junction box must always be locked. Access must only be
granted to authorised staff who have received corresponding
training and safety briefings.
If there are power supply faults, switch the EdEx thruster off
immediately.
WARNING
EdEx thrusters can reach housing surface temperatures of up
to 100 °C in continuous mode S1 or in very high switching
mode S3
Risk of burns on the housing surface
– Avoid touching the housing surface during operation.
– Wear safety gloves.
WARNING
Component failure
Risk of injury due to component failure
– There is the risk of individual components breaking when
operating the EdEx thruster. The lifting force failure can pose
subsequent hazards.
– The operating parameters must be adhered to.
– The EdEx thruster must be installed so that no forces can be
applied at an angle to the working direction.
Содержание ELDRO EdEx 125/160
Страница 2: ......