8
Help with malfunctions
8.1
Faults and troubleshooting
60
/ 75
ELDRO-EdEx-Montageanleitung-607338-EN.docx
Table 23:
Faults and troubleshooting
Fault
Possible cause
Measure
Lack of operating fluid
Top up the operating fluid
Operating fluid
escapes
On the lifting rod seal
Replace the EdEx thruster and send to
the manufacturer for repair
On the filling screw
Check the sealing ring, tighten the filling
screw to a maximum of 65 Nm
At the separation level between
cylinder jacket and end shield
Tighten the screw connection
to a maximum of 53 Nm
On the end shield or operating fluid in
the junction box
Replace the EdEx thruster and send to
the manufacturer for repair
Rattling, metallic
noise
Ball bearing damaged
Replace the EdEx thruster and send to
the manufacturer for repair
Motor protection
switch or fuse
elements tripped
Short-circuited coil, phase leakage or
short circuit
Check the motor’s resistors and
insulation, replace the EdEx thruster
and send to the manufacturer for repair
if required
Increased current
consumption, cause
Between two phases:
Short-circuited coil
Measure the resistance, replace the
EdEx thruster and send to the
manufacturer for repair if required
Between all phases:
Rotor is grinding or stuck
Replace the EdEx thruster and send to
the manufacturer for repair
Содержание ELDRO EdEx 125/160