9
Maintenance
9.2
Maintenance tasks
66
/ 75
ELDRO-EdEx-Montageanleitung-607338-EN.docx
9.2.5
Changing the operating fluid
WARNING
Hot operating fluid
Risk of burns due to hot oil plumes upon opening the filling screw
when at operational temperature.
– The operating fluid may only be checked, topped up or
drained when switched off and cool.
– The EdEx thruster may only opened at a maximum
temperature of 40 °C.
NOTICE
If not filled sufficiently, the thruster does not develop the full lifting
force.
If overfilled, the thruster’s internal pressure is impermissibly high.
Position the EdEx thruster vertically above a suitable collecting
container
Remove filler and drain plug.
After the thruster has been completely emptied, close the drainage
opening firmly again
New operating fluid (
⇒
data on type plate)
The explosion-proof EdEx thruster is filled correctly if the fluid
level reaches the lower edge within the filling opening when the
thruster is upright and the lifting rod is retracted.
Perform several lifting movements to avoid possible air pockets
Then check the fill level again and top up operating fluid if
necessary
Tightly close the filler plug when the required fill level is reached
Dispose of used liquid (
⇒
Disposal chapter).