Safety
2
Process media
2.7
ELDRO-EdEx-Montageanleitung-607338-EN.docx
21
/ 75
Check the voltage supply using the data on the type plate and
then establish the electrical connection according to the terminal
diagram on the inside of the terminal box frame. The phase
sequence is arbitrary. The earthing must maintain an earth
leakage resistance of < 10
6
Ω. The connection to the earthing
screw must be established with a suitable cable lug (minimum
cross section 4 mm
2
)
2.7
Process media
The instructions on the manufacturer’s material safety data
sheets must be followed.
Contact with eyes or the skin should be avoided.
Avoid inhaling vapours or mist.
Soak up any spilled or leaking process media immediately with a
binding agent and dispose of it properly.
Keep containers with flammable substances and compressed,
liquefied gases away from sources of heat.
2.8
Modifications
Changes, additions and modifications to EdEx components that could
impair safety or function are not permitted.
2.9
Spare and wear parts
The use of spare and wear parts from third-party manufacturers may
lead to risks. Only original parts or spare and wearing parts approved
by the manufacturer may be used.
For information regarding spare parts orders for EdEx types that
can no longer be supplied, see the “Ordering notes for
replacement thrusters”.
Содержание ELDRO EdEx 125/160