Assembly and installation
6
Electrical connection
6.2
ELDRO-EdEx-Montageanleitung-607338-EN.docx
47
/ 75
6.2
Electrical connection
DANGER
Live components
Fatal electric shock or serious burns
– Work on live components may only be performed by
electricians.
– When performing any work on electrical components, the five
safety rules must be adhered to:
– 1. Disconnect from the electrical supply
– 2. Safeguard to prevent a restart
– 3. Test to ensure a de-energised state
– 4. Earth and short-circuit
– 5. Cover or isolate adjacent live parts
– The earthing conductor must always be connected before all
other cables.
– Electrical power may only be supplied once the earthing
conductor is connected.
Standard requirements must be observed when connecting the
EdEx thruster.
Before connecting, check whether the mains voltage and the
mains frequency correspond to the specifications on the type
plate.
When selecting the connection cable (temperature resistance),
an excess temperature of +40 K to the ambient temperature
must be taken into account.
For cable entries (temperature resistance) an excess
temperature of +35 K to the ambient temperature must be taken
into account.
If there is a risk of mechanical damage, the cable must be
additionally protected (e.g. with a protective tube).
The cable diameter must be observed to ensure a tight
connection in the cable entry.
Содержание ELDRO EdEx 125/160