9
Maintenance
9.3
Maintenance schedule
68
/ 75
ELDRO-EdEx-Montageanleitung-607338-EN.docx
Test object
Test interval according to classification
Test
performed
Test
passed
Evaluation /
measured values
Proof of insulation
reliability in accordance
with DIN 57530 part 1 /
VDE 0530 section17.1
Every 2-3 years
Maintenance
Replacing all wear parts
(bearings, seals,
operating fluids, etc.)
Recommendation:
Every 5 years
or after
5 million switching cycles
Summary
Complete test passed
Repair required
Next test
Confirmation
The test was performed in accordance with the manufacturer’s maintenance manual.
Location/date
Company
Tester
Signature
9.3.1
Classification
Table 26:
Classification
Classification
Low requirements
Standard
Higher requirements
by safety profile
Applications in functions and
areas with low safety
requirements
Applications in functions and
areas with normal safety
requirements
Applications in functions and
areas with very high safety
requirements
or by operating profile
Mainly at a standstill, operation
irregular and seldom
Operated in average value
ranges of the permissible
operating data according to
type plate
Operated in limit value ranges
of the permissible operating
data according to type plate
Test run
Every six months
Visual checks
Annually
Annually
Every six months
Functional inspection
Annually
Annually
Extended test
Every 2-3 years
Recommendation:
Maintenance
Every 5 years or after 5 million switching cycles
Содержание ELDRO EdEx 125/160