Technical data
3.9
Airborne sound emissions
34
/ 75
ELDRO-EdEx-Montageanleitung-607338-EN.docx
3.9
Airborne sound emissions
The A-rated emission sound pressure level for all EdEx thrusters is
55 dB (A). This value was determined using an integrated sound
pressure level measuring unit in accordance with DIN 45633 under
the following measurement conditions:
The EdEx thruster (measurement object) ran continuously.
The measurement object was on a table around 0.8 m above the
ground
The measurement microphone was 1.6 m above the ground.
The diagonal gap between the measurement microphone/object
was 1 m.
3.10
Operating conditions
3.10.1
Ambient temperature
Explosion-proof EdEx thrusters are limited to the following ambient
temperatures depending on the hydraulic medium:
Table 20:
Ambient temperatures for EdEx thrusters
Temperature range
Usable EdEx thrusters
-10 °C to +40 °C
Special application
-40 °C to +40 °C
Low temperature
-25 °C to +40 °C
Standard
-10 °C to +60 °C
High temperature
3.10.2
Air humidity
With special measures, operation of EdEx thrusters is permitted up to
100 % humidity.
3.10.3
Aggressive ambient conditions
Special measures (special paint) are required for use in aggressive
ambient conditions (e.g. salty ambient air).
3.10.4
Installation height
The maximum permissible installation height is 1,000 m above sea
level unless otherwise specified on the type plate.