5.17.13 Fieldbus module category parameters
Table 5-39 Solutions Module error status values for Fieldbus modules
Below are the parameters that are common to all Fieldbus category modules. For more information, refer to the specific
Fieldbus Module User Guide
.
The menu for the relevant slot appears for the new Solutions Module category with the default parameter values for the new category.
When no Solutions Module is installed in the relevant slot this parameter is zero. When a Solutions Module is installed this parameter displays the
identification code.
401: SM-LON
403: SM-PROFIBUS DP
404: SM-INTERBUS
406: SM-CAN
407: SM-DeviceNet
408: SM-CANOpen
409: SM-SERCOS
410: SM-Ethernet
421: SM-Ethernet CAT
The new parameter values are not stored in the drive EEPROM until the user performs a parameter save by setting Pr xx.00 to 1000 and pressing the
stop/reset button. When parameters are saved by the user in the drive EEPROM, the option code of the currently installed Solutions Module is saved
in the drive EEPROM. If the drive is subsequently powered-up with a different Solutions Module installed, or no Solutions Module is installed when
one was previously installed, the drive will trip on SLx.dF or SLx.nF.
Error code
Module
Trip Description
0
All
No trip
1
SM-Ether CAT
No field bus mode has been selected
2
SM-Ether CAT
Critical task over-run
52
SM-PROFIBUS-DP, SM-Interbus,
SM-DeviceNet, SM-CANOpen
User control word trip
58
SM-LON
Incorrect non-volatile storage
61
SM-PROFIBUS-DP, SM-Interbus,
SM-DeviceNet, SM-CANOpen, SM-SERCOS
Configuration error
62
SM-Ether CAT
Database initialisation error
63
SM-Ether CAT
File system initialisation error
64
SM-DeviceNet
Expected packet rate timeout
65
SM-PROFIBUS-DP, SM-Interbus,
SM-DeviceNet, SM-CANOpen, SM-SERCOS
Network loss
66
SM-PROFIBUS-DP
Critical link failure
SM-CAN, SM-DeviceNet, SM-CANOpen
Bus off error
69
SM-CAN
No acknowledgement
70
All (except SM-Ethernet, SM-Ether CAT)
Flash transfer error
SM-Ethernet
No valid menu data available for the module from the drive
74
All
Solutions module over temperature
75
SM-Ethernet, SM-Ether CAT
The drive is not responding
76
SM-Ethernet, SM-Ether CAT
The Modbus connection has timed out
80
All (except SM-SERCOS)
Inter-option communications error
81
All (except SM-SERCOS)
Communications error to slot 1
82
All (except SM-SERCOS)
Communications error to slot 2
83
All (except SM-SERCOS)
Communications error to slot 3
84
SM-Ethernet, SM-Ether CAT
Memory allocation error
85
SM-Ethernet, SM-Ether CAT
File system error
86
SM-Ethernet, SM-Ether CAT
Configuration file error
87
SM-Ethernet, SM-Ether CAT
Language file error
98
All
Internal watchdog error
99
All
Internal software error
x.01
Solutions Module ID code
RO
Uni
PT
US
Ú
0 to 599
Ö
Update rate: Write on power-up