Parameter
structure
Keypad and
display
Parameter
x.00
Parameter
description format
Advanced parameter
descriptions
Macros
Serial comms
protocol
Electronic
nameplate
Performance RFC mode
Menus 15 to 17
SM-SLM
Unidrive SP Advanced User Guide
351
Issue Number: 10 www.controltechniques.com
If Pr
x.49
is set to 1, Pr
x.04
, Pr
x.05
and Pr
x.06
are not updated. If this parameter is set to 0 Pr
x.04
, Pr
x.05
and Pr
x.06
are updated normally.
The error status is provided so that only one option error trip is required for each Solutions Module slot. If an error occurs, the reason for the error is
written to this parameter and the drive may produce a ‘SLx.Er’ trip, where x is the slot number. A value of zero indicates that the Solutions Module has
not detected an error, a non-zero value indicates that an error has been detected. (See Table 5-37 on page 342) for the meaning of the values in this
parameter). When the drive is reset, this parameter is cleared for the relevant Solutions Module.
This Solutions Module includes a temperature monitoring circuit. If the PCB temperature exceeds 94
°
C, the drive fan is forced to operate at full speed
(for a minimum of 10s). If the temperature falls below 94
°
C, the fan can operate normally again. If the PCB temperature exceeds 100
°
C, the drive will
trip and the error status is set to 74.
The SM-SLM includes a processor with software. The software version is displayed in Pr
x.02
and Pr
x.51
in the form Pr
x.02
= xx.yy and Pr
x.51
=
zz.
Where:
xx specifies a change that affects hardware compatibility
yy specifies a change that affects product documentation
zz specifies a change that does not affect the product documentation
When a Solutions Module is installed that does not contain software, both Pr
x.02
and Pr
x.51
appear as zero.
x.49
Lock position feedback
RW
Bit
Ú
Ö
Drive modes: Host, Encoder only
Update rate: Combined update time. SM-SLM adds 4ms to the
combined update time
x.50
Solutions Module error status
RO
Uni
NC
PT
Ú
0 to 255
Ö
Update rate: Background write
x.51
Solutions Module software sub-version
RO
Uni
NC
PT
Ú
0 to 99
Ö
Update rate: Write on power-up