Menus 15 to 17
SM-SLM
Parameter
structure
Keypad and
display
Parameter
x.00
Parameter
description format
Advanced parameter
descriptions
Macros
Serial comms
protocol
Electronic
nameplate
Performance RFC mode
350
Unidrive SP Advanced User Guide
www.controltechniques.com Issue Number: 10
Host mode:
0 - NONE: No motor parameters have been sent to the UniSP
1 - MIN: Minimal parameters have been transferred so normal performance is possible
2 - FULL: All parameters have been transferred so high performance is possible
The EEPROM CRC check performed by the host is listened to by the SM-SLM which stores parameters ready to transfer to the drive. When Pr
x.28
is written to by the host, the appropriate stored EEPROM data is written to the drive parameters. If the host does not wish to use this function, nothing
or 0 should be written to Pr
x.28
.
Encoder only mode:
If Autotune mode is equal to one:
0 - MIN: Minimal parameters to be transferred so normal performance is possible
1 - MIN: Minimal parameters to be transferred so normal performance is possible
2 - FULL: All parameters to be transferred so high performance is possible
When loading using Pr
x.26
= 1, the parameter set loaded on power-up or restart depends on Pr
x.28
.
The parameter set is the same as was controlled by Pr
x.27
when saving was performed.
In Encoder only mode, a parameter transfer cannot be performed with the drive in either RUN or STOP.
Values of Pr
x.26
, Pr
x.27
and Pr
x.28
are read when Pr
x.29
= 1. The sequencer is reset to POWER_UP. Pr
x.29
is reset to 0 after the update - which
is very fast.
Sets Pr
3.26
to the slot with the SLM module in it as primary feedback.
Pr
5.18
to 8kHz switching frequency.
These are the only drive parameters that require setting when the drive has been defaulted.
The user must set Pr
3.40
and Pr
7.15
appropriately.
This parameter is reset to zero by the Solutions Module on completion.
Indicates that the axis has been correctly initialized and is ready to run.
•
Encoder only mode: Axis initialised active from sequencer status
•
Host mode: Axis initialised active from sequencer plus external motion controller
x.28
Parameters transferred
RW
Uni
US
Ú
0 to 2
Ö
0
Drive modes: Host, Encoder only
Update rate: Background
x.29
Action the tuning and saving parameters
RW
Txt
US
Ú
OFF (0) or On (1)
Ö
OFF (0)
Drive modes: Host, Encoder only
Update rate: Background
x.30
Automatic basic drive set-up request
RW
Uni
US
Ú
0 to 1
Ö
0
Drive modes: Host, Encoder only
Update rate: Background
x.45
Axis initialised
RO
Txt
PT
Ú
OFF (0) or On (1)
Ö
OFF (0)
Drive modes: Host, Encoder only
Update rate: Background
NOTE
NOTE
NOTE