The following modes are available for the analog input 2. In modes 2 & 3 a current loop loss trip is generated if the input current falls below 3mA.
In modes 2 and 4 the destination parameter is at a value equivalent to 0.0% when the input current is less than 4mA. In modes 3 and 5 the destination
parameter is at a value equivalent to 100.0% when the input current is less than 4mA.
7.11
T7 analog input 2 mode
Drive modes
Open-loop, Closed-loop vector, Servo, Regen
Coding
Bit
SP
FI
DE Txt VM DP ND RA NC NV
PT
US RW BU
PS
1
1
1
1
Range
Open-loop, Closed-loop vector, Servo,
Regen
0 to 6
Default
Open-loop, Closed-loop vector, Servo,
Regen
6
Update rate
Background read
Parameter
value
Parameter
string
Mode
Comments
0
0-20
0 - 20mA
1
20-0
20 - 0mA
2
4-20.tr
4 -20mA with trip on loss
Trip if I < 3mA, Pr
7.02
= 0.0% if I < 4mA
3
20-4.tr
20 - 4mA with trip on loss
Trip if I < 3mA, Pr
7.02
= 100.0% if I < 4mA
4
4-20
4 - 20mA with no trip on loss
Pr
7.02
= 0.0% if I < 4mA
5
20-4
20 - 4mA with no trip on loss
Pr
7.02
= 100.0% if I < 4mA
6
VOLt
Voltage mode
7.12
T7 analog input 2 scaling
Drive modes
Open-loop, Closed-loop vector, Servo, Regen
Coding
Bit
SP
FI
DE Txt VM DP
ND
RA NC NV
PT
US RW BU
PS
3
1
1
1
Range
Open-loop, Closed-loop vector, Servo,
Regen
0.000 to 4.000
Default
Open-loop, Closed-loop vector, Servo,
Regen
1.000
Update rate
Background read
7.13
T7 analog input 2 invert
Drive modes
Open-loop, Closed-loop vector, Servo, Regen
Coding
Bit
SP
FI
DE Txt VM DP
ND
RA NC NV
PT
US RW BU
PS
1
1
1
Default
Open-loop, Closed-loop vector, Servo,
Regen
0
Update rate
Background read
7.14
T7 analog input 2 destination
Drive modes
Open-loop, Closed-loop vector, Servo, Regen
Coding
Bit
SP
FI
DE Txt VM DP ND RA NC NV
PT
US RW BU
PS
1
2
1
1
1
1
Range
Open-loop, Closed-loop vector, Servo,
Regen
Pr
0.00
to Pr
21.51
Default
Open-loop, Closed-loop vector, Servo
Regen
Pr
1.37
Pr
3.10
Update rate
Read on drive reset
Содержание unidrive sp