123
Product Certifications
January 2017
Reference Manual
00809-0100-4140, Rev AA
Special conditions for use (X) (E1 and E8)
1. The user is to ensure the probe assembly is installed in such a
way to prevent any damage due to impact or ignition source
due to friction.
2. Non-standard paint options may cause risk from electrostatic
discharge. Avoid installations that could cause electrostatic
build-up of painted surfaces, and only clean the painted
surfaces with a damp cloth. If paint is ordered through a
special option code, contact the manufacturer for more
information.
3. Flameproof joints are not intended for repair.
Special conditions for use (X) (I1 and I8)
1. The equipment, when fitted with the transient suppression
terminal block, is not capable of withstanding the 500 volt
insulation test. This must be taken into account when
installing the equipment.
2. The enclosure may be made of aluminum alloy and given a
protective polyurethane paint finish. However, care should
be taken to protect it from impact or abrasion if located in
Zone 0.
3. The enclosure may be given a non-standard paint finish
which may constitute a potential electrostatic ignition risk.
Care should be taken to protect it from external conditions
conducive to the build-up of electrostatic charge on such
surfaces. The enclosure must not be rubbed or cleaned with
a dry cloth.
4. The enclosure may be given a non-standard paint finish
which may constitute a potential electrostatic ignition risk.
Care should be taken to protect it from external conditions
conducive to the build-up of electrostatic charge on such
surfaces. The enclosure must not be rubbed or cleaned with
a dry cloth.
Special conditions for use (X) (ND, E8, and I1)
1. Cable entries must maintain the ingress protection rating of
the enclosure to at least IP66.
2. Unused cable entries must be filled with suitable blanking
plugs which maintain the ingress protection of the enclosure
to at least IP66.
3. Cable entries and blanking plugs must be suitable for the
ambient temperature of the equipment and be capable of
withstanding a 7J impact test.
B.4.3 International
Note
For full product approvals information, refer to the
Rosemount 2140
Product Certifications Manual
.
E7
IECEx Flameproof and Dust
Certificates: IECEx DEK 16.0040X and IECEx BAS 16.0106X
Standards:
IEC60079-0:2011,
IEC60079-1:2014,
IEC60079-26:2014, and
IEC60079-31:2013
Markings:
Ex db IIC T6...T2 Ga/Gb
Ex ta IIIC (T92°C…T272°C) (T
500
100°C…T
500
280°C) Da
(
E7
also includes the
NK
approval)
I7
IECEx Intrinsically Safe
Certificate: IECEx BAS 16.0105X
Markings:
Ex ia IIC T5...T2 Ga
Standards:
IEC60079-0:2011 and IEC60079-11:2011
NK
IECEx Dust
Certificate: IECEx BAS 16.0106X
Standards:
IEC60079-0:2011 and IEC60079-31:2013
Markings:
Ex ta IIIC (T92°C…T272°C) (T
500
100°C…T
500
280°C) Da
Special conditions for use (X) (E7)
1. The user is to ensure the probe assembly is installed in such a
way to prevent any damage due to impact or ignition source
due to friction.
2. Non-standard paint options may cause risk from electrostatic
discharge. Avoid installations that could cause electrostatic
build-up of painted surfaces, and only clean the painted
surfaces with a damp cloth. If paint is ordered through a
special option code, contact the manufacturer for more
information.
3. Flameproof joints are not intended for repair.
Содержание Rosemount 2140
Страница 1: ...Reference Manual 00809 0100 4140 Rev AA January 2017 Rosemount 2140 Level Detector Vibrating Fork ...