Specifications and Reference Data
January 2017
Reference Manual
00809-0100-4140, Rev AA
118
Specifications and Reference Data
Terminal block
T1
Transient protection terminal block
★
Display
M4
LCD display with Local Operator Interface
★
Additional configuration buttons
(8)
DP
Device test (single button)
★
Special procedures
(9)
P1
Hydrostatic testing with certificate
★
Alarm levels
C4
Analog output levels compliant with NAMUR recommendation NE43, high alarm
★
C5
Analog output levels compliant with NAMUR recommendation NE43, low alarm
★
C1
Custom alarm and saturation signal levels (requires Configuration Data Sheet)
★
C8
Low alarm (standard Rosemount alarm and saturation levels)
★
HART revision configuration
HR7
Device configured for HART 7 communication protocol
★
Safety certification
(10)
QS
Prior-use certificate of FMEDA data
★
QT
(11)
Safety certificate to IEC61508
★
Example of options included with the model number: 2140 A H A 1 M S 1 NN B A 0000 1 NA Q4 Q8
1.
ECTFE copolymer coating is only available for a flanged Rosemount 2140 but excludes 1-in./DN25/25A flanges.
Flanges are dual certified 316 and 316L Stainless Steel (1.4401 and 1.4404).
2.
Not available for mechanically polished process-wetted parts.
3.
Minimum length available for
3
/
4
-in. threaded connection is 3.8 in. (95 mm); for 1-in. threaded, it is 3.7 in. (94 mm); for flanged, it is 3.5 in. (89 mm);
and for Tri Clamp, it is 4.1 in. (105 mm). Maximum length is 157.5 in. (4000 mm), except for ECTFE copolymer coating and hand-polished process where the maximum
length is 59.1 in. (1500 mm) and 39.4 in. (1000 mm) respectively. Examples: Code E1181 is 118.1 inches. Code M3000 is 3000 millimeters.
“Ordinary locations certifications” on page 123
. E5 includes G5 requirements. G5 is for unclassified, safe area locations only.
“Ordinary locations certifications” on page 123
. E6 includes G6 requirements. G6 is for unclassified, safe area locations only.
6.
Only available for process-wetted parts.
7.
The Extended Features Package includes Scaled Variables, Smart Diagnostics Suite, and Media Learn.
8.
Option DP only available for a Rosemount 2140 with Profile code A selected. This is not selectable if the Display code M4 is selected.
9.
Option limited to units with extended lengths up to 59.1-in. (1500 mm). Option is not available for ECTFE coating.
10. Available only for a Rosemount 2140:SIS (i.e. Profile code F selected).
11. The Rosemount 2140:SIS has been independently certified to IEC 61508 as required by IEC 61511. Certification was conducted by Exida. If documentation is required,
add “QT” to the end of the model number.
Содержание Rosemount 2140
Страница 1: ...Reference Manual 00809 0100 4140 Rev AA January 2017 Rosemount 2140 Level Detector Vibrating Fork ...
Страница 2: ......
Страница 8: ...VI Reference Manual 00809 0100 4140 Rev AA Contents January 2017 Contents ...
Страница 14: ...4 Reference Manual 00809 0100 4140 Rev AA Introduction January 2017 Introduction ...
Страница 112: ...102 Reference Manual 00809 0100 4140 Rev AA Troubleshooting January 2017 Troubleshooting ...
Страница 143: ......