January 2017
Reference Manual
00809-0100-4140, Rev AA
122
Product Certifications
I5
USA Intrinsic Safety (IS) and Non-Incendive (NI)
Certificate: CSA 16CA70098990X
Standards:
FM Class 3600 - 2011,
FM Class 3610 - 2015, and
FM Class 3611 - 2004
Markings:
Class I Groups A, B, C and D, T5…T2, Type 4X
Class I, Zone 0, AEx ia IIC T5…T2 Ga
Class I, Division 2, Groups A, B, C, and D
when connected using installation drawing 71097/1387
I6
Canada Intrinsic Safety and Non-Incendive
Certificate: CSA 16CA70098990X
Standards:
ANSI/ISA 12.27.01:2003,
CSA Std. C22.2 No. 157 -92,
CSA Std. C22.2 No.60079-0-15,
CSA Std. C22.2. No.60079-11-14, and
CSA Std. C22.2 No.213-M1987
Markings:
Class I Groups A, B, C and D, T5…T2, Type 4X
Ex ia IIC T5…T2 Ga
Class I, Division 2, Groups A, B, C, and D
when connected using installation drawing 71097/1387
Special conditions for use (X) (I5 and I6)
1. The equipment, when fitted with the transient suppression
terminal block, is not capable of withstanding the 500 volt
insulation test. This must be taken into account when
installing the equipment.
2. The enclosure may be made of aluminum alloy and given a
protective polyurethane paint finish. However, care should
be taken to protect it from impact or abrasion if located in
Zone 0.
3. The enclosure may be given a non-standard paint finish
which may constitute a potential electrostatic ignition risk.
Care should be taken to protect it from external conditions
conducive to the build-up of electrostatic charge on such
surfaces. The enclosure must not be rubbed or cleaned with a
dry cloth.
B.4.2 Europe
Note
For full product approvals information, refer to the
Rosemount 2140
Product Certifications Manual
.
E1
ATEX
Flameproof
Certificate: Dekra 16ATEX0082X
Standards:
EN60079-0:2012+A11:2013,
EN60079-1:2014, and
EN60079-26:2015
Markings:
II 1/2 G, Ex db IIC T6...T2 Ga/Gb
ND
ATEX Dust
Certificate: Baseefa 16ATEX0137X
Standards:
EN60079-0:2012+A11:2013 and EN60079-31:2014
Markings:
II 1 D Ex ta IIIC (T92°C…T272°C) (T
500
100°C…T
500
280°C) Da
E8
Combines
E1
and
ND
I1
ATEX Intrinsically Safe and Dust (Zone 0, 20)
Certificates:
Baseefa 16ATEX0136X and Baseefa 16ATEX0137X
Standards:
EN60079-0:2012+A11:2013,
EN60079-11:2012,
EN60079-26:2015, and
EN60079-31:2014
Markings:
II 1 G, Ex ia IIC T5...T2 Ga
II 1 D Ex ta IIIC (T92...T272°C) (T
500
100°C...T
500
280°C) Da
(
I1
includes the
ND
approval)
I8
ATEX Intrinsically Safe (Zone 1)
Certificate: Baseefa 16ATEX0136X
Standards:
EN60079-0:2012+A11:2013,
EN60079-11:2012, and
EN60079-26:2015
Markings:
II 1/2 G, Ex ia IIC T5...T2 Ga/Gb
Содержание Rosemount 2140
Страница 1: ...Reference Manual 00809 0100 4140 Rev AA January 2017 Rosemount 2140 Level Detector Vibrating Fork ...
Страница 2: ......
Страница 8: ...VI Reference Manual 00809 0100 4140 Rev AA Contents January 2017 Contents ...
Страница 14: ...4 Reference Manual 00809 0100 4140 Rev AA Introduction January 2017 Introduction ...
Страница 112: ...102 Reference Manual 00809 0100 4140 Rev AA Troubleshooting January 2017 Troubleshooting ...
Страница 143: ......