January 2017
Reference Manual
00809-0100-4140, Rev AA
126
Figure C-2. Rosemount 2140 Field Communicator Menu Tree (Configure Part One)
1. Basic Setup
2. Display
3. Process Alerts (*2)
4. Scaled Variable (*1)
5. Burst Mode
6. Power Advisory (*2)
1. Guided Setup
2. Manual Setup
3. Alert Setup
1. Operation
2. Analog Output
3. Scaled Variable (*1)
4. Device Temperature
5. Display
6. HART
7. Security
8. Frequency Profiling (*2)
9. Device Information
1. Output State
2. Sensor State
3. Sensor Frequency
4. Scaled Variable
(*1)
5. Electronics Temperature
6. Terminal Voltage
7. Percent of Range
8. Analog Output
9. Review Parameters at Start.
1. Type: Custom
(*3)
2. Alarm Direction
3. High Alarm
4. High Saturation
5. Low Saturation
6. Low Alarm
7. Config Alarm/Sat Levels
1. Application
2. Device Test (*5)
3. Sensor
1. Output State
2. Sensor State
3. Sensor Frequency
4. Scaled Variable (*1)
5. Electronics Temperature
6. Terminal Voltage
3. Service Tools
1. Sensor Operating Mode
2. Sensor Output Delay
3. Media Density
4. Learnt
(*2)
5. Media Learn
(*2)
1. Duration
2. Start-up Device Test (*9)
1. Allowable Change in
Dry Fork Frequency
2. Sensor Fault Delay
1. Overview
2. Configure
(*3)
Types can be “NAMUR”, “Rosemount ”, or “Custom”.
(*4)
Available only when operating as a HART
7 device
.
(*6)
Available only when operating as a HART
5 device
.
(*5)
Proof Test on Rosemount 2140:SIS.
(*7)
Start-up Proof Test on Rosemount 2140:SIS.
1. Burst Message 1
(*4)
2. Message 1 Content
(*4)
1. Burst Message 1
(*6)
2. Message 1 Content
(*6)
3. Message 1 Variables
(*6)
1. Power Advisory Settings
2. Loop Power Characteriz.
1. Terminal Voltage
2. Terminal Voltage Derivation Limit
3. Action
4. Reset Alert
1. Resistance
2. Power Supply
3. Characterize Loop
1. First and Trigger Variable
2. Secondary Variable
3. Tertiary Variable
4. Quaternary Variable
1. Primary Variable
2. Upper Range Value
3. Lower Range Value
1. PV Upper Limit
2. PV Lower Limit
3. PV Minimum Span
1. Analog Output
2. Percent of Range
1. Mode Setup
2. Set Range Points
3. Sensor Limits
4. Readings
5. Alarm/Saturation Levels
1. Current Output Type
2. Current Output
Operating Mode
3. Custom Off Current
4. Custom On Current
1. SV Data Points
2. SV Units
3. SV Transfer Function
5. Scaled Variable
1. Electronics Temperature
2. Status
(*4)
3. Unit
4. Maximum
5. Minimum
1. Output State
2. Sensor State
3. Sensor Frequency
4. Scaled Variable
(*1)
5. Electronics Temperature
6. Terminal Voltage
7. Percent of Range
8. Analog Output
9. Review Parameters at St.
1. SV Data Points
2. SV Units
3. SV Transfer Function
4. SV Linear Offset
5. Scaled Variable
1. Configure Alert
2. Alert Mode
3. Sensor State
4. High Alert Value
5. Low Alert Value
1. Configure Alert
2. Alert Mode
3. Output State
4. High Alert Value
5. Low Alert Value
1. Configure Alert
2. Alert Mode
3. Sensor Frequency
4. High Alert Value
5. Low Alert Value
1. Configure Alert
2. Alert Mode
3. Scaled Variable
4. High Alert Value
5. Low Alert Value
1. Configure Alert
2. Alert Mode
3. Electronics Temperature
4. Low Alert Value
5. Low Alert Value
1. Configure Alert
2. Alert Mode
3. Terminal Voltage
4. High Alert Value
5. Low Alert Value
(*1)
Available on a Rosemount 2140 with the
Extended Features Package (EFP).
(*2)
Available with the Extended Features Package (EFP)
on a Rosemount 2140 or Rosemount 2140:SIS.
.
4. SV Linear Offset
Содержание Rosemount 2140
Страница 1: ...Reference Manual 00809 0100 4140 Rev AA January 2017 Rosemount 2140 Level Detector Vibrating Fork ...
Страница 2: ......
Страница 8: ...VI Reference Manual 00809 0100 4140 Rev AA Contents January 2017 Contents ...
Страница 14: ...4 Reference Manual 00809 0100 4140 Rev AA Introduction January 2017 Introduction ...
Страница 112: ...102 Reference Manual 00809 0100 4140 Rev AA Troubleshooting January 2017 Troubleshooting ...
Страница 143: ......