6.5
Troubleshooting
6.5.1
Does not switch
Symptom or indication
LED is not lit, no power.
Recommended actions
1. Check the power supply.
2. Check the load on direct load switching electronics model.
Symptom or indication
LED is flashing three times per second.
Recommended actions
Contact Emerson to report an internal PCB fault is being indicated.
Symptom or indication
LED is flashing once every two seconds.
Recommended actions
Contact Emerson to report an uncalibrated device is being indicated.
Symptom or indication
LED is flashing once every four seconds.
Recommended actions
Check the electrical installation for a load fault (current is too high or a short-circuit).
Symptom or indication
Visual inspection found fork damage.
Recommended actions
Contact Emerson to report the damage and discuss how to get a replacement.
Symptom or indication
Visual inspection found thick encrustation on the forks.
Recommended actions
Carefully clean the fork.
Symptom or indication
There is always a five second delay after changing the mode or delay.
Recommended actions
This is a normal function when making any changes to the settings.
Reference Manual
Service and troubleshooting
00809-0100-4030
March 2022
Rosemount 2120 Level Switch
59
Содержание Rosemount 2120
Страница 1: ...Reference Manual 00809 0100 4030 Rev GA March 2022 Rosemount 2120 Level Switch Vibrating Fork ...
Страница 4: ...4 ...
Страница 8: ...Introduction Reference Manual March 2022 00809 0100 4030 8 Reference Manual ...
Страница 14: ...Level switch overview Reference Manual March 2022 00809 0100 4030 14 Reference Manual ...
Страница 32: ...Mechanical installation Reference Manual March 2022 00809 0100 4030 32 Reference Manual ...
Страница 81: ...Reference Manual 00809 0100 4030 March 2022 Rosemount 2120 Level Switch 81 ...