Insulation
Figure 3-6: Insulation
A
A
B
A. 3.9 in. (100 mm) clearance all around
B. ROCKWOOL
®
Pipe installation requirements
•
The inside pipe diameter (D) must be 1.4 in. (35 mm) or larger.
•
Ensure the fork tines intrude at least 0.9 in. (22 mm) into the pipe.
•
Keep at least 0.3 in. (7 mm) of clearance between the fork tines and the pipe wall.
Figure 3-7: Pipe Installation
D
A
B
A. Minimum intrusion 0.9 in. (22 mm)
B. Minimum clearance 0.3 in. (7 mm)
Mechanical installation
Reference Manual
March 2022
00809-0100-4030
22