3.3.2
Correct fork alignment
Fork alignment in a pipe installation
The fork is correctly aligned by positioning the groove or notch as indicated (
Figure 3-13: Correct Fork Alignment for Pipe Installation
A
B
A
B
OK
OK
A. Tri Clamp process connections have a circular notch
B. Threaded process connections have a groove
Fork alignment in a vessel (tank) installation
The fork is correctly aligned by positioning the groove or notch as indicated (
Figure 3-14: Correct Fork Alignment for Vessel (Tank) Installation
A
B
C
OK
OK
OK
A. Tri Clamp process connections have a circular notch
B. Threaded process connections have a groove
C. Flanged process connections have a circular notch
Reference Manual
Mechanical installation
00809-0100-4030
March 2022
Rosemount 2120 Level Switch