Menu
11
Parameter
Parameter description
protocol
Performance
structure
Keypad
and
format
Advanced
parameter
descriptions
Serial
comms
Read-only
function
Data
blocks
with
numbers
from
1
to
499
can
be
created
or
erased
by
the
user.
Data
block
with
numbers
500
and
above
are
read-only
and
cannot
be
created
or
erased
by
the
user.
The
whole
card
may
also
be
protected
from
writing
or
erasing
by
setting
the
read-only
flag.
If
the
card
or
a
data
block
on
the
card
is
read-only,
then
the
operation
to
erase
the
whole
card
is
disabled.
Different
voltage
ratings
If
the
voltage
rating
of
the
source
and
destination
drive
are
different
then
the
parameters
are
transferred
with
the
exception
of
rating
dependent
parameters
(RA
attribute
set,
see
table
below),
which
are
left
at
their
default
values.
In
this
case
a
C.rtg
trip
is
given
as
a
warning
that
this
has
happened.
It
is
possible
to
suppress
this
warning
trip
for
any
data
transfer
to
the
drive,
including
a
boot
transfer
at
power-up
by
setting
the
warning
suppression
flag
for
the
whole
card.
Different
Solutions
Modules
installed
If
the
categories
of
the
Solutions
Modules
installed
to
the
source
drive
are
different
to
the
destination
drive
then
the
parameters
are
transferred
with
the
exception
of
the
parameters
in
the
menus
of
the
modules
that
are
different.
These
parameters
are
left
at
their
default
values.
In
this
case
a
C.Optn
trip
is
given
as
a
warning.
It
is
possible
to
suppress
this
warning
trip
for
any
data
transfer
to
the
drive,
including
a
boot
transfer
at
power-up
by
setting
the
warning
suppression
flag
for
the
whole
card.
Different
current/voltage
rating
with
a
parameter
file
type
data
block
If
the
current
or
voltage
ratings
of
the
source
and
destination
drive
are
different
and
the
parameters
stored
as
a
parameter
file
(not
differences
from
default)
then
rating
dependant
parameters
are
set
to
their
defaults
and
a
C.rtg
trip
is
produced
as
described
above
where
the
voltage
ratings
are
different.
It
is
possible
to
suppress
this
warning
trip
for
any
data
transfer
to
the
drive,
including
a
boot
transfer
at
power-up
by
setting
the
warning
suppression
flag
for
the
whole
card.
Effects
of
variable
maximums
if
ratings
or
options
are
different
It
should
be
noted
that
if
ratings
of
the
source
and
destination
drives
are
different,
or
the
Solutions
Modules
installed
to
the
source
and
destination
drives
are
different,
it
is
possible
that
some
parameters
with
variable
maximums
may
be
limited
and
not
have
the
same
values
as
on
the
card.
For
example
the
user
current
maximum
scaling
(Pr
4.24)
is
rating
dependent
and
could
be
set
to
its
default
value
when
it
is
transferred
between
drives
of
different
ratings,
but
this
could
also
affect
the
torque
reference
(Pr
4.08)
as
this
uses
Pr
4.24
as
its
maximum.
Also
different
position
feedback
Solutions
Modules
can
apply
different
limits
on
the
speed
references,
therefore
these
can
be
affected
when
parameters
are
transferred
between
drives
with
different
position
feedback
Solutions
Modules
installed
where
the
Solutions
Module
is
being
used
for
the
drive
position
feedback.
Product
identifier
The
product
identifier
is
written
to
the
card
when
the
whole
card
is
erased.
If
the
identifier
does
not
match
the
drive
product
and
the
card
contains
any
data
blocks
a
C.Prod
trip
is
produced.
Also
if
the
following
functions
are
initiated
a
C.Acc
trip
is
produced
and
the
card
or
drive
data
is
not
affected:
erase
file,
transfer
data
block
from
card
to
drive,
or
transfer
data
block
from
drive
to
card.
It
is
still
possible
to
use
Pr
11.37
to
browse
information
about
the
whole
card
(i.e.
Pr
11.37
=
1000
to
1003),
but
it
is
not
possible
to
see
the
data
block
information
(i.e.
Pr
11.37
<
1000).
It
is
also
possible
to
change
the
card
header
information
(i.e.
read-only
flag
and
warning
suppression
flag).
This
feature
allows
the
read-only
flag
to
be
cleared
so
that
a
card
can
be
erased
to
be
used
with
the
product
that
performs
the
card
erase.
If
the
card
does
not
contain
any
data
blocks
(i.e.
an
erased
card)
and
the
identifier
does
not
match
that
of
the
drive
then
the
drive
will
automatically
change
the
identifier
on
the
card
to
match
when
it
is
first
inserted.
150
Mentor
MP
Advanced
User
Guide
www.onxcontrol.com
Issue
Number:
4
11.38
SMARTCARD
data
type/mode
Coding
Bit
SP
FI
DE
TE
VM
DP
ND
RA
NC
NV
PT
US
RW
BU
PS
1
1
1
1
1
Range
0
to
18
Update
rate
Background
write
Parameter
number
Function
Pr
4.05
to
Pr
4.07
Current
limits
Pr
4.24
User
current
maximum
scaling
Pr
5.07
{SE07,
0.28}
Motor
rated
current
Pr
5.09
{SE06,
0.27}
Armature
rated
voltage
Product
Product
Identifier
Unidrive
SP
(standard)
255
Digitax
ST
2
Affinity
3
Mentor
MP
4
Содержание Mentor MP
Страница 8: ...Menu 4 4 07 150 Mentor MP Advanced User Guide 7 Issue Number 4 www onxcontrol com ...
Страница 38: ...Mentor MP Advanced User Guide 35 Issue Number 4 www onxcontrol com ...
Страница 221: ......
Страница 222: ...0476 0002 04 ...