Parameter x.00
Parameter
protocol
Performance
Menu
5
Parameter
structure
Keypad
and
description
format
Advanced
parameter
descriptions
Serial
comms
Figure
5-7
Parallel
12
Pulse
Three
phase
transformer
Fuses*
Master
drive
Slave
drive
E1
E3
F+
F-
E1
E3
F+
F-
Motor
field
winding
Motor
armature
Interbridge
reactor
*For
fuse
information
please
refer
to
section
4.6
in
the
Mentor
MP
User
Guide.
To
configure
the
drives
for
use
in
a
parallel
12
pulse
speed
control
system,
they
should
be
programmed
so
that
the
master
drive
is
set
up
in
speed
control
mode
(Pr
4.11
=
0),
and
the
slave
drive
is
programmed
in
torque
control
mode
(Pr
4.11
=
1).
The
final
current
demand
(Pr
4.04)
on
the
master
drive
has
to
be
fed
in
to
the
slave
drive
torque
reference
(Pr
4.08).
This
current
demand
signal
can
be
transferred
between
the
drives
using
either
an
analog
input
/
output,
communication
module
or
by
using
CT
Sync.
Additional
bridge
interlocking
signals
are
shared
between
the
two
modules,
when
a
four
quadrant
system
is
required
to
ensure
that
the
same
bridge
on
both
drives
is
firing
and
also
that
the
current
has
reached
zero
on
both
drives
before
current
reversal
is
attempted.
NOTE
Only
terminals
relevant
to
12
pulse
operation
have
been
shown.
80
Mentor
MP
Advanced
User
Guide
www.onxcontrol.com
Issue
Number:
4