4
Trip
Diagnosis
EnC9
Drive
encoder
trip:
Position
feedback
is
selected
from
a
Solutions
Module
slot
which
does
not
have
a
speed
/
position
feedback
Solutions
Module
installed
197
Check
setting
of
Pr
3.26
(Fb01,
0.71)
(or
Pr
21.21
if
the
second
motor
parameters
have
been
enabled)
EnC10
Drive
encoder
trip:
Termination
overload
198
If
the
voltage
from
the
encoder
is
>5
V,
then
the
termination
resistors
must
be
disabled
(Pr
3.39
to
0)
Et
External
trip
6
Check
terminal
31
signal
Check
value
of
Pr
10.32
Enter
12001
in
Pr
xx.00
and
check
for
parameter
controlling
Pr
10.32
Ensure
Pr
10.32
or
Pr
10.38
(=6)
are
not
being
controlled
by
serial
comms
FbL
No
feedback
from
the
tachometer
or
encoder
159
If
the
difference
between
the
estimated
speed
(Pr
5.04)
and
the
actual
speed
feedback
(Pr
3.02
(di05,
0.40))
exceeds
the
value
set
in
the
speed
feedback
loss
window
(Pr
3.56)
the
drive
will
trip
Feedback
loss.
With
fast
acceleration
rates
in
applications
with
low
load
intertia
estimated
speed
(Pr
5.04)
may
not
track
the
actual
speed
feedback
(Pr
3.02
(di05,
0.40))
fast
enough
and
the
speed
feedback
loss
window
(Pr
3.56)
may
need
to
be
increased.
Check
the
feedback
device
is
connected
correctly
Check
motor
name
plate
values
have
been
entered
into
the
drive
correctly
Check
the
speed
feedback
in
estimated
speed
mode
-
refer
to
running
a
motor
section
checking
speed
feedback
Carry
out
a
rotating
autotune
Fbr
The
polarity
of
the
feedback
tachometer
or
encoder
is
incorrect
160
Check
that
the
feedback
devices
are
connected
correctly
FdL
No
current
in
the
field
supply
circuit
168
Check
that
the
field
controller
(Pr
5.77
(SE12,
0.33))
is
enabled.
For
the
internal
field
controller
check
terminals
L11,
L12
are
closed
Check
internal
auxiliary
fuses.
FOC
Excess
current
detected
in
field
current
feedback
169
Maximum
current
feedback
is
present
Check
Field
rated
current
(Pr
5.70
(SE10,
0.31))
and
Field
rated
voltage
(Pr
5.73
(SE11,
0.32))
are
set
correct
to
motor
nameplate
Check
for
short
circuit
on
field
circuit
cabling
Check
integrity
of
motor
insulation
F.OVL
2
Field
I
t
overload
157
See
Pr
5.81
and
Pr
5.82
HF01
Data
processing
error:
CPU
address
error
Hardware
fault
-
return
drive
to
supplier
HF02
Data
processing
error:
DMAC
address
error
Hardware
fault
-
return
drive
to
supplier
HF03
Data
processing
error:
Illegal
instruction
Hardware
fault
-
return
drive
to
supplier
HF04
Data
processing
error:
Illegal
slot
instruction
Hardware
fault
-
return
drive
to
supplier
HF05
Data
processing
error:
Undefined
exception
Hardware
fault
-
return
drive
to
supplier
HF06
Data
processing
error:
Reserved
exception
Hardware
fault
-
return
drive
to
supplier
HF07
Data
processing
error:
Watchdog
failure
Hardware
fault
-
return
drive
to
supplier
HF08
Data
processing
error:
Level
4
crash
Hardware
fault
-
return
drive
to
supplier
HF09
Data
processing
error:
Heap
overflow
Hardware
fault
-
return
drive
to
supplier
HF10
Data
processing
error:
Router
error
Hardware
fault
-
return
drive
to
supplier