Parameter
structure
Keypad
and
display
Parameter
x.00
Parameter
description
protocol
Performance
Typical
example
parameter
The
top
row
gives
the
menu.parameter
number
and
the
parameter
name.
The
other
rows
give
the
following
information.
The
coding
defines
the
attributes
of
the
parameter
as
follows:
format
Advanced
parameter
descriptions
Serial
comms
4
Parameter
description
format
The
following
sections
provide
descriptions
for
the
advanced
parameter
set.
Each
parameter
displays
the
following
information
block
as
shown
below.
Coding
NOTE
This
guide
will
show
all
bit
parameters
(with
the
Bit
coding),
as
having
a
parameter
range
of
"0
to
1",
and
a
default
value
of
either
"0"
or
"1".
This
reflects
the
value
seen
through
serial
communications.
The
bit
parameters
will
be
displayed
on
the
SM-Keypad
or
SM-Keypad
Plus
(if
used)
as
being
"OFF"
or
"On"
("OFF"=
0,
"On"
=
1).
Mentor
MP
Advanced
User
Guide
17
Issue
Number:
4
www.onxcontrol.com
Coding
Attribute
Bit
1
bit
parameter
SP
Spare:
not
used
FI
Filtered:
some
parameters
which
can
have
rapidly
changing
values
are
filtered
when
displayed
on
the
drive
keypad
for
easy
viewing.
DE
Destination:
indicates
that
this
parameter
can
be
a
destination
parameter.
Txt
Text:
the
parameter
uses
text
strings
instead
of
numbers.
VM
Variable
maximum:
the
maximum
of
this
parameter
can
vary.
DP
Decimal
place:
indicates
the
number
of
decimal
places
used
by
this
parameter.
ND
No
default:
when
defaults
are
loaded
(except
when
the
drive
is
manufactured
or
on
EEPROM
failure)
this
parameter
is
not
modified.
RA
Rating
dependent:
this
parameter
is
likely
to
have
different
values
and
ranges
with
drives
of
different
voltage
and
current
ratings.
Parameters
with
this
attribute
will
not
be
transferred
to
the
destination
drive
by
SMARTCARDs
when
the
rating
of
the
destination
drive
is
different
from
the
source
drive
and
the
file
is
a
parameter
file.
NC
Not
copied:
not
transferred
to
or
from
SMARTCARDs
during
copying.
NV
Not
visible:
not
visible
on
the
keypad.
PT
Protected:
cannot
be
used
as
a
destination.
US
User
save:
saved
in
drive
EEPROM
when
the
user
initiates
a
parameter
save.
RW
Read/write:
can
be
written
by
the
user.
BU
Bit
default
one/unsigned:
Bit
parameters
with
this
flag
set
to
one
have
a
default
of
one
(all
other
bit
parameters
have
a
default
of
zero.
Non-bit
parameters
are
unipolar
if
this
flag
is
one.
PS
Power-down
save:
parameter
automatically
saved
in
drive
EEPROM
when
the
under
volts
(UV)
trip
occurs.
1.14
Reference
selector
Coding
Bit
SP
FI
DE
Txt
VM
DP
ND
RA
NC
NV
PT
US
RW
BU
PS
1
1
1
1
Range
0
to
6
Default
0
(A1.A2)
Second
motor
parameter
Pr
21.03
Update
rate
4
ms
read
Содержание Mentor MP
Страница 8: ...Menu 4 4 07 150 Mentor MP Advanced User Guide 7 Issue Number 4 www onxcontrol com ...
Страница 38: ...Mentor MP Advanced User Guide 35 Issue Number 4 www onxcontrol com ...
Страница 221: ......